Percutaneous radiologically guided gastrostomy tube placement: comparison of antegrade transoral and retrograde transabdominal approaches.

IF 2.1 4区 医学 Q2 Medicine Diagnostic and Interventional Radiology Pub Date : 2017-01-01 DOI:10.5152/dir.2016.15626
Z. Haber, H. Charles, J. Gross, Daniel Pflager, A. Deipolyi
{"title":"Percutaneous radiologically guided gastrostomy tube placement: comparison of antegrade transoral and retrograde transabdominal approaches.","authors":"Z. Haber, H. Charles, J. Gross, Daniel Pflager, A. Deipolyi","doi":"10.5152/dir.2016.15626","DOIUrl":null,"url":null,"abstract":"PURPOSE We aimed to compare the antegrade transoral and the retrograde transabdominal approaches for fluoroscopy-guided percutaneous gastrostomy tube (G-tube) placement. METHODS Following institutional review board approval, all G-tubes at two academic hospitals (January 2014 to May 2015) were reviewed retrospectively. Retrograde approach was used at Hospital 1 and both antegrade and retrograde approaches were used at Hospital 2. Chart review determined type of anesthesia used during placement, dose of radiation used, fluoroscopy time, procedure time, medical history, and complications. RESULTS A total of 149 patients (64 women, 85 men; mean age, 64.4±1.3 years) underwent G-tube placement, including 93 (62%) placed via the retrograde transabdominal approach and 56 (38%) placed via the antegrade transoral approach. Retrograde placement entailed fewer anesthesiology consultations (P < 0.001), less overall procedure time (P = 0.023), and less fluoroscopy time (P < 0.001). A comparison of approaches for placement within the same hospital demonstrated that the retrograde approach led to significantly reduced radiation dose (P = 0.022). There were no differences in minor complication rates (13%-19%; P = 0.430), or major complication rates (6%-7%; P = 0.871) between the two techniques. CONCLUSION G-tube placement using the retrograde transabdominal approach is associated with less fluoroscopy time, procedure time, radiation exposure, and need for anesthesiology consultation with similar safety profile compared with the antegrade transoral approach. Additionally, it is hypothesized that decreased procedure time and anesthesiology consultation using the transoral approach are likely associated with reduced cost.","PeriodicalId":50582,"journal":{"name":"Diagnostic and Interventional Radiology","volume":"23 1 1","pages":"55-60"},"PeriodicalIF":2.1000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5152/dir.2016.15626","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Interventional Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/dir.2016.15626","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 9

Abstract

PURPOSE We aimed to compare the antegrade transoral and the retrograde transabdominal approaches for fluoroscopy-guided percutaneous gastrostomy tube (G-tube) placement. METHODS Following institutional review board approval, all G-tubes at two academic hospitals (January 2014 to May 2015) were reviewed retrospectively. Retrograde approach was used at Hospital 1 and both antegrade and retrograde approaches were used at Hospital 2. Chart review determined type of anesthesia used during placement, dose of radiation used, fluoroscopy time, procedure time, medical history, and complications. RESULTS A total of 149 patients (64 women, 85 men; mean age, 64.4±1.3 years) underwent G-tube placement, including 93 (62%) placed via the retrograde transabdominal approach and 56 (38%) placed via the antegrade transoral approach. Retrograde placement entailed fewer anesthesiology consultations (P < 0.001), less overall procedure time (P = 0.023), and less fluoroscopy time (P < 0.001). A comparison of approaches for placement within the same hospital demonstrated that the retrograde approach led to significantly reduced radiation dose (P = 0.022). There were no differences in minor complication rates (13%-19%; P = 0.430), or major complication rates (6%-7%; P = 0.871) between the two techniques. CONCLUSION G-tube placement using the retrograde transabdominal approach is associated with less fluoroscopy time, procedure time, radiation exposure, and need for anesthesiology consultation with similar safety profile compared with the antegrade transoral approach. Additionally, it is hypothesized that decreased procedure time and anesthesiology consultation using the transoral approach are likely associated with reduced cost.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经皮放射学引导下胃造口管置入:顺行经口入路与逆行经腹入路的比较。
目的比较透视引导下经口顺行入路和经腹逆行入路在经皮胃造口管(g管)置入中的应用。方法回顾性分析2014年1月至2015年5月两所学术医院的所有g管。医院1采用逆行入路,医院2采用顺行和逆行入路。图表回顾确定放置时使用的麻醉类型,使用的放射剂量,透视时间,手术时间,病史和并发症。结果共149例患者,其中女性64例,男性85例;平均年龄(64.4±1.3岁)行g管置入,其中经腹逆行入路93例(62%),经口逆行入路56例(38%)。逆行放置需要更少的麻醉学咨询(P < 0.001),更少的总手术时间(P = 0.023)和更少的透视时间(P < 0.001)。同一医院内放置路径的比较表明,逆行路径可显著降低辐射剂量(P = 0.022)。两组轻微并发症发生率无差异(13%-19%;P = 0.430),或主要并发症发生率(6%-7%;P = 0.871)。结论:与顺行经口入路相比,逆行经腹入路置管的透视时间、手术时间、辐射暴露和麻醉学咨询需要更少,安全性相似。此外,假设使用经口入路减少手术时间和麻醉咨询可能与降低成本有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
69
审稿时长
6-12 weeks
期刊介绍: Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English. The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.
期刊最新文献
Application of deep learning and radiomics in the prediction of hematoma expansion in intracerebral hemorrhage: a fully automated hybrid approach. Diagnostic value of qualitative and quantitative enhancement parameters on contrast-enhanced mammography. Post-contrast abdominal magnetic resonance imaging of critically ill patients using compressed sensing free-breathing golden radial angle imaging. The effect of MWA protocols upon morphology and IVIM parameters of hepatic ablation zones-a preliminary in vivo animal study with an MRI-compatible microwave ablation device. Percutaneous sclerotherapy using a 4 F pigtail catheter and 40 milliliters of 5% ethanolamine oleate for symptomatic large hepatic cysts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1