Another alternate integrated circuit approach to modulation of radiofrequency transmission signals in magnetic resonance imaging

IF 0.9 4区 医学 Q4 CHEMISTRY, PHYSICAL Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering Pub Date : 2017-12-08 DOI:10.1002/cmr.b.21359
Benson Yang, Fred Tam, Clare McElcheran, Simon J. Graham
{"title":"Another alternate integrated circuit approach to modulation of radiofrequency transmission signals in magnetic resonance imaging","authors":"Benson Yang,&nbsp;Fred Tam,&nbsp;Clare McElcheran,&nbsp;Simon J. Graham","doi":"10.1002/cmr.b.21359","DOIUrl":null,"url":null,"abstract":"<p>Parallel radiofrequency transmission has garnered much attention for its wide range of benefits in magnetic resonance imaging (MRI), including reduced power deposition and radiofrequency excitation with improved spatial uniformity. However, few pTx systems are commercially available and most are expensive. This manuscript introduces another alternative parallel transmit architecture at 3 T based on field-programmable gate array technology, and explores the utility of a low cost, integrated circuit approach to signal modulation that is easily scaled to high channel counts. The technical and engineering specifications of a complete 4-channel signal modulation module are presented in detail, including radiofrequency characterization and MRI results. The experimental results are additionally compared to a commercially available 4-channel modulation system. The findings indicate that the proposed device is easy to use, provides fine control of phase and amplitude on existing MRI systems, and can be fabricated for approximately 30 USD per channel. Initial estimates suggest that the complete 4-channel modulation system (including the required software licenses and multi-function reconfigurable input/output devices) can be implemented for approximately 10 000 USD.</p>","PeriodicalId":50623,"journal":{"name":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","volume":"47B 3","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2017-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/cmr.b.21359","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cmr.b.21359","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 2

Abstract

Parallel radiofrequency transmission has garnered much attention for its wide range of benefits in magnetic resonance imaging (MRI), including reduced power deposition and radiofrequency excitation with improved spatial uniformity. However, few pTx systems are commercially available and most are expensive. This manuscript introduces another alternative parallel transmit architecture at 3 T based on field-programmable gate array technology, and explores the utility of a low cost, integrated circuit approach to signal modulation that is easily scaled to high channel counts. The technical and engineering specifications of a complete 4-channel signal modulation module are presented in detail, including radiofrequency characterization and MRI results. The experimental results are additionally compared to a commercially available 4-channel modulation system. The findings indicate that the proposed device is easy to use, provides fine control of phase and amplitude on existing MRI systems, and can be fabricated for approximately 30 USD per channel. Initial estimates suggest that the complete 4-channel modulation system (including the required software licenses and multi-function reconfigurable input/output devices) can be implemented for approximately 10 000 USD.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
磁共振成像中射频传输信号调制的另一种替代集成电路方法
平行射频传输因其在磁共振成像(MRI)中的广泛优势而受到广泛关注,包括减少功率沉积和提高空间均匀性的射频激励。然而,很少有pTx系统是商用的,而且大多数都很昂贵。本文介绍了另一种基于现场可编程门阵列技术的3t并行传输架构,并探讨了低成本集成电路方法对信号调制的实用性,该方法易于扩展到高通道数。详细介绍了一个完整的4通道信号调制模块的技术和工程规格,包括射频特性和MRI结果。实验结果还与市售的四通道调制系统进行了比较。研究结果表明,该装置易于使用,可以在现有的MRI系统上对相位和幅度进行精细控制,并且每个通道的制造成本约为30美元。初步估计表明,完整的4通道调制系统(包括所需的软件许可证和多功能可重构输入/输出设备)可以实现约10,000美元。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
3
审稿时长
>12 weeks
期刊介绍: Concepts in Magnetic Resonance Part B brings together engineers and physicists involved in the design and development of hardware and software employed in magnetic resonance techniques. The journal welcomes contributions predominantly from the fields of magnetic resonance imaging (MRI), nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR), but also encourages submissions relating to less common magnetic resonance imaging and analytical methods. Contributors come from both academia and industry, to report the latest advancements in the development of instrumentation and computer programming to underpin medical, non-medical, and analytical magnetic resonance techniques.
期刊最新文献
Impact of Patient Body Posture on RF-Induced Energy Absorption by Orthopedic Plates Odd-Leg Birdcages for Geometric Decoupling in Multinuclear Imaging and Spectroscopy A General Framework for Automated Accurate Calculation of b-Matrix (Auto-b) in Diffusion MRI Pulse Sequences Development of Electron Paramagnetic Resonance Magnet System for In Vivo Tooth Dosimetry Diagnosis of Alzheimer’s Disease with Extreme Learning Machine on Whole-Brain Functional Connectivity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1