Bin Cheng, Chao Tan, Xiuying Tang, X. Leng, Zheyu Chu
{"title":"Design of Deicing Device for Air Vent of Cold Storage","authors":"Bin Cheng, Chao Tan, Xiuying Tang, X. Leng, Zheyu Chu","doi":"10.12783/dtetr/mcaee2020/35033","DOIUrl":null,"url":null,"abstract":"Due to the cold storage vents are the intersection of outdoor warm flow and indoor cold flow, there is often ice accumulation. In this paper, we design one deicing device for air vent of cold storage which can automatically detect the icing condition of the vent and heat and deice the steel tube. The device includes contact sensor, power module, I/O acquisition module, control module, heating copper tube and leakage protection switch. When the contact sensor is completely covered with ice, the contact sensor sends out an alarm signal. The signal is transmitted to the I/O acquisition module and to the control module to drive the heating copper tube to automatically heat and deice. This design can be widely used in unmanaged cold storage vents and indoor and outdoor temperature environment of the warehouse with a large difference.","PeriodicalId":11264,"journal":{"name":"DEStech Transactions on Engineering and Technology Research","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEStech Transactions on Engineering and Technology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12783/dtetr/mcaee2020/35033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Due to the cold storage vents are the intersection of outdoor warm flow and indoor cold flow, there is often ice accumulation. In this paper, we design one deicing device for air vent of cold storage which can automatically detect the icing condition of the vent and heat and deice the steel tube. The device includes contact sensor, power module, I/O acquisition module, control module, heating copper tube and leakage protection switch. When the contact sensor is completely covered with ice, the contact sensor sends out an alarm signal. The signal is transmitted to the I/O acquisition module and to the control module to drive the heating copper tube to automatically heat and deice. This design can be widely used in unmanaged cold storage vents and indoor and outdoor temperature environment of the warehouse with a large difference.