Fiber Sensor for Simultaneous Measurement of Heart and Breath Rate on SmartBed

N. R. Amalia, A. Hatta, S. Koentjoro, A. Nasution, I. Puspita
{"title":"Fiber Sensor for Simultaneous Measurement of Heart and Breath Rate on SmartBed","authors":"N. R. Amalia, A. Hatta, S. Koentjoro, A. Nasution, I. Puspita","doi":"10.1109/ICP46580.2020.9206491","DOIUrl":null,"url":null,"abstract":"Heart and breath rate are fundamental vital signs used for early detection in cardiac events. In this work, a sensor based on singlemode-multimode-singlemode (SMS) fiber structure was designed, fabricated, and tested for simultaneous measurement of heart and breath rate on a bed. A signal processing was used for obtaining the heart rate from the output signal of SMS fiber structure. In order to reduce noise in the heart rate signal, a Butterworth filter was employed. The results show that the proposed SMS fiber structure as a sensor has a relative error of 11% and 6% for measuring the heart and breath rate, respectively. The SMS fiber sensor gives a potency to measure the heart and breath rate simultaneously on a smart bed and suitable to be used in home and hospital.","PeriodicalId":6758,"journal":{"name":"2020 IEEE 8th International Conference on Photonics (ICP)","volume":"60 1","pages":"68-69"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 8th International Conference on Photonics (ICP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICP46580.2020.9206491","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Heart and breath rate are fundamental vital signs used for early detection in cardiac events. In this work, a sensor based on singlemode-multimode-singlemode (SMS) fiber structure was designed, fabricated, and tested for simultaneous measurement of heart and breath rate on a bed. A signal processing was used for obtaining the heart rate from the output signal of SMS fiber structure. In order to reduce noise in the heart rate signal, a Butterworth filter was employed. The results show that the proposed SMS fiber structure as a sensor has a relative error of 11% and 6% for measuring the heart and breath rate, respectively. The SMS fiber sensor gives a potency to measure the heart and breath rate simultaneously on a smart bed and suitable to be used in home and hospital.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于同时测量智能床上心跳和呼吸速率的光纤传感器
心率和呼吸频率是早期发现心脏事件的基本生命体征。本文设计、制作并测试了一种基于单模-多模-单模(SMS)光纤结构的传感器,用于在床上同时测量心率和呼吸频率。采用信号处理的方法,从SMS光纤结构的输出信号中获取心率。为了降低心率信号中的噪声,采用了巴特沃斯滤波器。结果表明,所提出的SMS光纤结构作为传感器测量心率和呼吸频率的相对误差分别为11%和6%。SMS光纤传感器提供了在智能床上同时测量心率和呼吸频率的能力,适合在家庭和医院使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Temperature Sensor based on 1D SiN/Air Photonic Crystal Research on reconstruction algorithm of lensless microimaging High spatial resolution microscopy with functional thin film Fiber Sensor for Simultaneous Measurement of Heart and Breath Rate on SmartBed Photoluminescence and Raman Studies on $\mathrm{GaAs}_{1-\mathrm{x}}\mathrm{Bi}_{\mathrm{X}}$ Grown on GaAs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1