Revised stability criteria for cascaded DC-DC converters in space applications

M. Triggianese, H. Carbonnier, F. Tonicello
{"title":"Revised stability criteria for cascaded DC-DC converters in space applications","authors":"M. Triggianese, H. Carbonnier, F. Tonicello","doi":"10.1109/ESPC.2019.8932078","DOIUrl":null,"url":null,"abstract":"The Middlebrook's criteria is used in the ECSS-E-ST −20C (European Cooperation for Space Standardization - Electrical and Electronic) to guarantee the stability of cascaded power systems. It is worth noticing that the non-compliance to Middlebrook's criterion does not represent a necessary condition for stability, therefore when not satisfied, additional analysis might be necessary to check the stability margins. It is however a very conservative approach. Other less conservative methods have been proposed for the interconnection of feedback controlled DC/DC converters. Among others, a revised criterion is considered in this paper and different study-cases are analyzed to demonstrate the typical situations that a power engineer is facing with cascaded DC-DC power supplies.","PeriodicalId":6734,"journal":{"name":"2019 European Space Power Conference (ESPC)","volume":"157 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 European Space Power Conference (ESPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESPC.2019.8932078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The Middlebrook's criteria is used in the ECSS-E-ST −20C (European Cooperation for Space Standardization - Electrical and Electronic) to guarantee the stability of cascaded power systems. It is worth noticing that the non-compliance to Middlebrook's criterion does not represent a necessary condition for stability, therefore when not satisfied, additional analysis might be necessary to check the stability margins. It is however a very conservative approach. Other less conservative methods have been proposed for the interconnection of feedback controlled DC/DC converters. Among others, a revised criterion is considered in this paper and different study-cases are analyzed to demonstrate the typical situations that a power engineer is facing with cascaded DC-DC power supplies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
修订的空间应用级联DC-DC变换器稳定性标准
Middlebrook的标准用于ECSS-E-ST - 20C(欧洲空间标准化合作-电气和电子),以保证级联电力系统的稳定性。值得注意的是,不符合Middlebrook准则并不代表稳定性的必要条件,因此,当不满足时,可能需要额外的分析来检查稳定裕度。然而,这是一种非常保守的方法。对于反馈控制的DC/DC变换器的互连,已经提出了其他不太保守的方法。其中,本文考虑了一个修订的准则,并分析了不同的研究案例,以展示电力工程师面对级联直流电源的典型情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Four-Junction Wafer Bonded Solar Cells for Space Applications Back Reflector with Diffractive Gratings for Light-Trapping in Thin-Film III-V Solar Cells Degradation of Lithium-Ion Batteries in Aerospace Design and Optimization of Radiation-Hardened Isolated Converters for Jovian Environments Narrow Bandgap Dilute Nitride Materials for 6-junction Space Solar Cells
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1