Mehmet Eskibağlar, Serkan Erdem, M. O. Kaman, M. Ocak
{"title":"Finite element analysis of bending and torsional loading of two different endodontic rotary files with different off-center geometric sections","authors":"Mehmet Eskibağlar, Serkan Erdem, M. O. Kaman, M. Ocak","doi":"10.1515/mt-2023-0070","DOIUrl":null,"url":null,"abstract":"Abstract The aim of this study was to evaluate the performance of two endodontic rotary files with different off-center geometries in bending and torsional tests using finite element analysis (FEA). Trunatomy Prime (TRN-P) and WaveOne Gold Primary (WOG-P) files were used in the study. Geometric models for finite element analysis were obtained by micro-computed tomography scanning. FEA analyses were performed according to ISO 3630-1 specifications to evaluate the bending and torsional tests of the files. Trunatomy Prime showed higher flexibility than WOG-P when subjected to bending. In terms of torsional strength, WOG-P showed higher torsional strength than TRN-P. The geometry of a rotary instrument file influences the mechanical behavior (bending and torsion) of rotary files. The clinician should be aware of the behavioral differences in rotary files and use the appropriate file according to the clinical situation in addition to the manufacturer’s instructions.","PeriodicalId":18231,"journal":{"name":"Materials Testing","volume":"1 1","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2023-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Testing","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1515/mt-2023-0070","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract The aim of this study was to evaluate the performance of two endodontic rotary files with different off-center geometries in bending and torsional tests using finite element analysis (FEA). Trunatomy Prime (TRN-P) and WaveOne Gold Primary (WOG-P) files were used in the study. Geometric models for finite element analysis were obtained by micro-computed tomography scanning. FEA analyses were performed according to ISO 3630-1 specifications to evaluate the bending and torsional tests of the files. Trunatomy Prime showed higher flexibility than WOG-P when subjected to bending. In terms of torsional strength, WOG-P showed higher torsional strength than TRN-P. The geometry of a rotary instrument file influences the mechanical behavior (bending and torsion) of rotary files. The clinician should be aware of the behavioral differences in rotary files and use the appropriate file according to the clinical situation in addition to the manufacturer’s instructions.
期刊介绍:
Materials Testing is a SCI-listed English language journal dealing with all aspects of material and component testing with a special focus on transfer between laboratory research into industrial application. The journal provides first-hand information on non-destructive, destructive, optical, physical and chemical test procedures. It contains exclusive articles which are peer-reviewed applying respectively high international quality criterions.