Application of the environmentally friendly technology for the removal of PCBs from mineral oils and power transformers to achieve very low values of PCBs for repair and materials recycling

D. Mihajlović, J. Janković, V. Vasović, V. Ivancevic, J. Lukić
{"title":"Application of the environmentally friendly technology for the removal of PCBs from mineral oils and power transformers to achieve very low values of PCBs for repair and materials recycling","authors":"D. Mihajlović, J. Janković, V. Vasović, V. Ivancevic, J. Lukić","doi":"10.5937/zeint32-41260","DOIUrl":null,"url":null,"abstract":"The Republic of Serbia signed and ratified the Stockholm Convention on Persistent Organic Pollutants. Law on ratification of the Stockholm Convention was adopted and actions were defined through the National Implementation Plan and the Action Plan. On their basis Project Proper Management and Final Disposal of Polychlorinated Biphenyls (PCBs) was created. Institute Nikola Tesla (INT) participated in the realization of the project. In the period from 2015 to 2022, 601 tons of PCB oil was successfully decontaminated by the INT mobile plant, i.e. the PCB content was below 50 mg/kg, which classified the power transformers (PT) as non-contaminated [1,2]. If PT becomes waste or in case of necessary repair or oil regeneration, the required limit value is 10 mg/kg. According to data from INT database there are still 2637 PTs containing PCBs in the concentration range of 2 to 50 mg/kg. In this paper application of the environmentally closed INT decontamination technology for achieving low values of PCB in the oil is shown.","PeriodicalId":31629,"journal":{"name":"Zbornik Radova Elektrotehnicki Institut Nikola Tesla","volume":"134 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zbornik Radova Elektrotehnicki Institut Nikola Tesla","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/zeint32-41260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Republic of Serbia signed and ratified the Stockholm Convention on Persistent Organic Pollutants. Law on ratification of the Stockholm Convention was adopted and actions were defined through the National Implementation Plan and the Action Plan. On their basis Project Proper Management and Final Disposal of Polychlorinated Biphenyls (PCBs) was created. Institute Nikola Tesla (INT) participated in the realization of the project. In the period from 2015 to 2022, 601 tons of PCB oil was successfully decontaminated by the INT mobile plant, i.e. the PCB content was below 50 mg/kg, which classified the power transformers (PT) as non-contaminated [1,2]. If PT becomes waste or in case of necessary repair or oil regeneration, the required limit value is 10 mg/kg. According to data from INT database there are still 2637 PTs containing PCBs in the concentration range of 2 to 50 mg/kg. In this paper application of the environmentally closed INT decontamination technology for achieving low values of PCB in the oil is shown.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用环保技术,从矿物油和电力变压器中去除多氯联苯,以达到极低的多氯联苯含量,以便维修和物料回收
塞尔维亚共和国签署并批准了《关于持久性有机污染物的斯德哥尔摩公约》。通过了批准《斯德哥尔摩公约》的法律,并通过《国家执行计划》和《行动计划》确定了行动。在此基础上,建立了多氯联苯项目的妥善管理和最终处置。尼古拉特斯拉研究所(INT)参与了该项目的实现。2015年至2022年,INT移动装置成功净化了601吨PCB油,即PCB含量低于50 mg/kg,将电力变压器(PT)列为无污染[1,2]。如果PT成为废物或在必要的修理或油再生情况下,要求的极限值为10 mg/kg。根据INT数据库的数据,仍有2637个pt含有浓度范围在2至50毫克/公斤的多氯联苯。本文介绍了环境封闭型INT去污技术在实现石油中PCB低值方面的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
90
审稿时长
4 weeks
期刊最新文献
Computer model analysis of dynamic performances of the excitation control system when the load angle limiter is active Insulation stresses of power equipment exposed to non-standard overvoltage waveforms Application of the environmentally friendly technology for the removal of PCBs from mineral oils and power transformers to achieve very low values of PCBs for repair and materials recycling The reliability of serial data communication using Uart-Usb converter Calculation of protection function settings of new elements of the 500 kV transmission system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1