Indentation of Articular Cartilage: Effects of Specimen Radius on Determined Properties

C. Spoon, J. Wayne
{"title":"Indentation of Articular Cartilage: Effects of Specimen Radius on Determined Properties","authors":"C. Spoon, J. Wayne","doi":"10.1115/imece2001/bed-23058","DOIUrl":null,"url":null,"abstract":"\n The indentation test is a commonly used experimental setup to determine properties of articular cartilage, both in the laboratory and as a clinical tool, as it is a test that can be performed in situ. Behavior of normal cartilage and tissue generated in reparative studies have been thus obtained [1, 2, 3]. It has been shown from a finite element study [4] that the behavior of cartilage in indentation stress relaxation can be affected by the tissue width relative to the radius of the indenter. Another finite element study of the indentation of osteochondral defects showed that this ratio also affected specifications of boundary conditions [5]. This investigation sought to evaluate the effect of changing geometric parameters (e.g. tissue width and indenter radius) on the properties determined from creep indentation experiments.","PeriodicalId":7238,"journal":{"name":"Advances in Bioengineering","volume":"28 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2001-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Bioengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2001/bed-23058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The indentation test is a commonly used experimental setup to determine properties of articular cartilage, both in the laboratory and as a clinical tool, as it is a test that can be performed in situ. Behavior of normal cartilage and tissue generated in reparative studies have been thus obtained [1, 2, 3]. It has been shown from a finite element study [4] that the behavior of cartilage in indentation stress relaxation can be affected by the tissue width relative to the radius of the indenter. Another finite element study of the indentation of osteochondral defects showed that this ratio also affected specifications of boundary conditions [5]. This investigation sought to evaluate the effect of changing geometric parameters (e.g. tissue width and indenter radius) on the properties determined from creep indentation experiments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
关节软骨的压痕:试样半径对确定性能的影响
压痕测试是一种常用的实验装置,用于确定关节软骨的特性,无论是在实验室还是作为临床工具,因为它是一种可以在原位进行的测试。因此,修复研究中产生的正常软骨和组织的行为已经得到[1,2,3]。一项有限元研究[4]表明,软骨在压痕应力松弛中的行为会受到相对于压痕半径的组织宽度的影响。另一项骨软骨缺陷压痕的有限元研究表明,该比值也会影响边界条件的规格[5]。本研究旨在评估改变几何参数(如组织宽度和压头半径)对蠕变压痕实验确定的性能的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of Graft Material on Anterior Cruciate Ligament Reconstruction: A 3D Computational Simulation A “Point Cloud” Approach in Superelastic Stent Design Biomechanical Properties of Grown Cartilage Are Decreased in the Presence of Retinoic Acid, Chondroitinase ABC and Ibuprofen Building Cellular Microenvironments to Control Capillary Endothelial Cell Proliferation, Death, and Differentiation Mechanical Factors Can Influence the Gender Differences in the Incidence of Non-Contact Injuries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1