Single artery pressure-lumen volume curve and compliance using flexible diaphragm tonometry

G. Drzewiecki, V. Bansal, J.K.-J. Li
{"title":"Single artery pressure-lumen volume curve and compliance using flexible diaphragm tonometry","authors":"G. Drzewiecki, V. Bansal, J.K.-J. Li","doi":"10.1109/IEMBS.1995.575040","DOIUrl":null,"url":null,"abstract":"An arterial tonometer is introduced that can measure arterial compliance as well as pressure. The flexible diaphragm tonometer employs volume feedback control such that the contact surface is apparently rigid. When feedback is disabled, electrical impedance plethysmography of the tonometer compartment permits simultaneous measurement of pressure and volume change in the underlying artery. Applanation pressure is varied in addition to provide compliance as function of pressure. Further analysis yields the arterial pressure-lumen volume curve characteristics.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1995.575040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

An arterial tonometer is introduced that can measure arterial compliance as well as pressure. The flexible diaphragm tonometer employs volume feedback control such that the contact surface is apparently rigid. When feedback is disabled, electrical impedance plethysmography of the tonometer compartment permits simultaneous measurement of pressure and volume change in the underlying artery. Applanation pressure is varied in addition to provide compliance as function of pressure. Further analysis yields the arterial pressure-lumen volume curve characteristics.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单动脉压力-管腔容积曲线及柔性隔膜张力计依从性
介绍了一种既能测量动脉顺应性又能测量动脉压力的动脉血压计。柔性膜片眼压计采用体积反馈控制,使接触面显然是刚性的。当反馈被禁用时,电阻抗容积描记仪可以同时测量基底动脉的压力和容积变化。压平压力是变化的,除了提供顺应性作为压力的功能。进一步分析得出动脉压-管腔容积曲线特征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Automatic seizure detection in newborns and infants Functional conditioning of skeletal muscle ventricles Electrical interactions between cardiac cells studied with "model clamp" An intelligent airway sensor system to increase safety in computer controlled mechanical ventilation A distributed health information network for consultative services in surgical pathology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1