Monitoring of breathing tube position and patency in situ using reflected sound 利用反射声原位监测呼吸管位置和通畅
J. P. Mansfield, G. R. Wodicka
A new technique that acoustically interrogates an intubated breathing tube to yield clinically useful patency and position information was developed. A miniature speaker connected to the proximal tube end generates a sonic pulse that propagates down the tube, and the resulting echoes from within the tube and airways are measured by a miniature microphone. During intubations of anesthetized canines, the technique: 1) reliably differentiated between tracheal, bronchial, and esophageal intubations; 2) accurately quantified tube movements; 3) provided the location and degree of lumenal obstructions; and 4) detected extubation or disconnection from the ventilator hose. This technique offers an inexpensive and noninvasive mechanism to monitor breathing tubes in situ.
一种新的技术,声学询问插管呼吸管,以产生临床上有用的通畅和位置信息。连接到管道近端的微型扬声器产生声波脉冲,该脉冲沿着管道传播,由此产生的来自管道和气道内的回声由微型麦克风测量。在麻醉犬的插管中,该技术:1)可靠地区分气管插管、支气管插管和食管插管;2)精确量化管的运动;3)提供管腔阻塞的位置和程度;4)检测到呼吸机软管拔管或断开。这项技术提供了一种廉价且无创的机制来原位监测呼吸管。
{"title":"Monitoring of breathing tube position and patency in situ using reflected sound","authors":"J. P. Mansfield, G. R. Wodicka","doi":"10.1109/IEMBS.1995.575313","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575313","url":null,"abstract":"A new technique that acoustically interrogates an intubated breathing tube to yield clinically useful patency and position information was developed. A miniature speaker connected to the proximal tube end generates a sonic pulse that propagates down the tube, and the resulting echoes from within the tube and airways are measured by a miniature microphone. During intubations of anesthetized canines, the technique: 1) reliably differentiated between tracheal, bronchial, and esophageal intubations; 2) accurately quantified tube movements; 3) provided the location and degree of lumenal obstructions; and 4) detected extubation or disconnection from the ventilator hose. This technique offers an inexpensive and noninvasive mechanism to monitor breathing tubes in situ.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73781291","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
QRS detection using a fuzzy neural network QRS检测采用模糊神经网络
K. P. Cohen, W. Tompkins, A. Djohan, J. Webster, Y.H. Hu
We developed a QRS detection algorithm which uses a fuzzy neural network (FNN) to process lead II recordings of the ECG. We trained and tested our algorithm using the MIT/BIH arrhythmia database, and compared our results to existing algorithms. For tapes 100, 105 and 108, our FNN reduced the total number of combined false-positive and false-negative detections from 174 to 44.
我们开发了一种QRS检测算法,该算法使用模糊神经网络(FNN)处理心电导联II记录。我们使用MIT/BIH心律失常数据库训练和测试我们的算法,并将我们的结果与现有算法进行比较。对于磁带100、105和108,我们的FNN将假阳性和假阴性检测的总数从174个减少到44个。
{"title":"QRS detection using a fuzzy neural network","authors":"K. P. Cohen, W. Tompkins, A. Djohan, J. Webster, Y.H. Hu","doi":"10.1109/IEMBS.1995.575064","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575064","url":null,"abstract":"We developed a QRS detection algorithm which uses a fuzzy neural network (FNN) to process lead II recordings of the ECG. We trained and tested our algorithm using the MIT/BIH arrhythmia database, and compared our results to existing algorithms. For tapes 100, 105 and 108, our FNN reduced the total number of combined false-positive and false-negative detections from 174 to 44.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73782550","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Image technique for wound assessment 伤口评估的图像技术
B.K. McQuiston, J.J. Whitestone, M. Stytz, J. Bishop, R. Henderson
Describes a technique for capturing wound characteristics with a laser surface scanning system. Analysis using both range and color information from this image is used to measure specific wound features. These wound features can be evaluated over time for determination of wound progression and as wound response to therapy.
描述了一种用激光表面扫描系统捕捉伤口特征的技术。利用该图像的范围和颜色信息进行分析,用于测量特定的伤口特征。这些伤口特征可以随着时间的推移进行评估,以确定伤口进展和伤口对治疗的反应。
{"title":"Image technique for wound assessment","authors":"B.K. McQuiston, J.J. Whitestone, M. Stytz, J. Bishop, R. Henderson","doi":"10.1109/IEMBS.1995.575226","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575226","url":null,"abstract":"Describes a technique for capturing wound characteristics with a laser surface scanning system. Analysis using both range and color information from this image is used to measure specific wound features. These wound features can be evaluated over time for determination of wound progression and as wound response to therapy.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75208446","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Artificial neural networks for estimation of joint angle from EMG signals 基于肌电信号的关节角度估计的人工神经网络
S. Suryanarayanan, N. P. Reddy, V. Gupta
A set of neural networks was developed for EMG based control of telemanipulators. The neural network system provides an estimate of the joint angle at the elbow using surface EMG of biceps in real time. The joint angle was measured by a goniometer to calibrate the system and train the networks. Preliminary results during testing indicate an error of less than 20% between the joint angle estimate of the network and the actual joint angle.
开发了一套基于肌电图控制的神经网络。该神经网络系统利用二头肌表面肌电信号实时估计肘关节角度。通过测角仪测量关节角度,对系统进行标定和网络训练。初步测试结果表明,网络的关节角估计值与实际关节角之间的误差小于20%。
{"title":"Artificial neural networks for estimation of joint angle from EMG signals","authors":"S. Suryanarayanan, N. P. Reddy, V. Gupta","doi":"10.1109/IEMBS.1995.575381","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575381","url":null,"abstract":"A set of neural networks was developed for EMG based control of telemanipulators. The neural network system provides an estimate of the joint angle at the elbow using surface EMG of biceps in real time. The joint angle was measured by a goniometer to calibrate the system and train the networks. Preliminary results during testing indicate an error of less than 20% between the joint angle estimate of the network and the actual joint angle.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75439288","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Artificial cells containing genetically engineered E. coli DH5 cells for urea and ammonia removal in kidney and liver failure 含有基因工程大肠杆菌DH5细胞的人工细胞用于肾脏和肝脏衰竭的尿素和氨的去除
S. Prakash, T. Chang
Describes a novel method of urea and ammonia removal using microencapsulated genetically engineered E. coli DH5 cells. In vitro, 100 mg of bacterial cells encapsulated in alginate-polylysine-alginate (APA) membrane, in their log phase state of growth, can lower 87.89/spl plusmn/2.25% of the plasma urea within 20 minutes and 99.99% in 30 minutes. The same amount of encapsulated bacteria is also capable of lowering ammonia from 975.14/spl plusmn/70.15 /spl mu/M/L to 81.151/spl plusmn/7.37 /spl mu/M/L in 30 minutes. This new approach is significantly more efficient than the presently available methods of urea and ammonia removal.
描述了一种利用微囊化基因工程大肠杆菌DH5细胞去除尿素和氨的新方法。在体外,100 mg被海藻酸-聚赖氨酸-海藻酸盐(APA)膜包裹的细菌细胞,在其log相生长状态下,在20分钟内可降低87.89/spl plusmn/2.25%的血浆尿素,在30分钟内可降低99.99%。同样数量的包封细菌也能在30分钟内将氨从975.14/spl plusmn/70.15 /spl mu/M/L降低到81.151/spl plusmn/7.37 /spl mu/M/L。这种新方法明显比目前可用的尿素和氨去除方法更有效。
{"title":"Artificial cells containing genetically engineered E. coli DH5 cells for urea and ammonia removal in kidney and liver failure","authors":"S. Prakash, T. Chang","doi":"10.1109/IEMBS.1995.579913","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579913","url":null,"abstract":"Describes a novel method of urea and ammonia removal using microencapsulated genetically engineered E. coli DH5 cells. In vitro, 100 mg of bacterial cells encapsulated in alginate-polylysine-alginate (APA) membrane, in their log phase state of growth, can lower 87.89/spl plusmn/2.25% of the plasma urea within 20 minutes and 99.99% in 30 minutes. The same amount of encapsulated bacteria is also capable of lowering ammonia from 975.14/spl plusmn/70.15 /spl mu/M/L to 81.151/spl plusmn/7.37 /spl mu/M/L in 30 minutes. This new approach is significantly more efficient than the presently available methods of urea and ammonia removal.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75837274","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The deformity plane determination and shape approximation of long bones from bi-planar radiographic 长骨双平面x线片的畸形面测定和形状近似
Hong Lin, J. Birch, M.L. Samchukov
A new procedure to determine the deformity plane for long bone from bi-planar radiographic and to approximate its shape on that plane is developed. This procedure can be used for the preoperative planning of angular deformity correction of long bones, especially the tibia or femur. The bone outline obtained in this procedure is used for the authors' Preoperative Planning System for angular deformity correction planning. By using this procedure, the third radiographic on the actual deformity plane can be omitted.
提出了一种利用双平面x线片确定长骨畸形平面并在该平面上近似其形状的新方法。该程序可用于长骨,特别是胫骨或股骨的角畸形矫正的术前计划。在此过程中获得的骨轮廓用于作者的术前计划系统进行角畸形矫正计划。通过使用这种方法,可以省去实际畸形平面的第三次x线摄影。
{"title":"The deformity plane determination and shape approximation of long bones from bi-planar radiographic","authors":"Hong Lin, J. Birch, M.L. Samchukov","doi":"10.1109/IEMBS.1995.575243","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575243","url":null,"abstract":"A new procedure to determine the deformity plane for long bone from bi-planar radiographic and to approximate its shape on that plane is developed. This procedure can be used for the preoperative planning of angular deformity correction of long bones, especially the tibia or femur. The bone outline obtained in this procedure is used for the authors' Preoperative Planning System for angular deformity correction planning. By using this procedure, the third radiographic on the actual deformity plane can be omitted.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75866412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A dedicated microprocessor for externally powered implantable pain controller 用于外部供电的植入式疼痛控制器的专用微处理器
M. Wei, J. Mouine, R. Fontaine, F. Duval
A 8-channel dedicated microprocessor for externally powered implantable pain control stimulator is presented. It is designed with 8 channels to deliver the stimuli: any subset out of 8 channels can be started or stopped simultaneously. Arbitrary current waveforms can be generated through appropriate programming which can be achieved by an algorithm serially transmitted transdermally. The microprocessor can be configured as biphasic or monophasic or mix operation mode. Particularly, the charge balanced biphasic pulses are easily generated. The design is accomplished with Verilog HDL language description at RTL level. The resulting schematic or netlist is then automatically placed and routed by Preview Cell Ensemble with the 1.5 micron Mitel process.
介绍了一种用于外接电源植入式疼痛控制刺激器的8通道专用微处理器。它设计有8个通道来传递刺激:8个通道中的任何一个子集都可以同时启动或停止。通过适当的编程可以产生任意的电流波形,该波形可以通过透皮串行传输的算法来实现。微处理器可配置为双相或单相或混合操作模式。特别是电荷平衡的双相脉冲很容易产生。在RTL层采用Verilog HDL语言描述完成设计。由此产生的原理图或网表然后自动放置和路由预览单元集成与1.5微米Mitel工艺。
{"title":"A dedicated microprocessor for externally powered implantable pain controller","authors":"M. Wei, J. Mouine, R. Fontaine, F. Duval","doi":"10.1109/IEMBS.1995.579566","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579566","url":null,"abstract":"A 8-channel dedicated microprocessor for externally powered implantable pain control stimulator is presented. It is designed with 8 channels to deliver the stimuli: any subset out of 8 channels can be started or stopped simultaneously. Arbitrary current waveforms can be generated through appropriate programming which can be achieved by an algorithm serially transmitted transdermally. The microprocessor can be configured as biphasic or monophasic or mix operation mode. Particularly, the charge balanced biphasic pulses are easily generated. The design is accomplished with Verilog HDL language description at RTL level. The resulting schematic or netlist is then automatically placed and routed by Preview Cell Ensemble with the 1.5 micron Mitel process.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74475412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Calculation of microwave radiometric signal in multilayered biological tissue 多层生物组织中微波辐射信号的计算
H. Hinrikus, J. Krasavin, K. Beilenhoff, H. Hartnagel
A spatial distribution of radiometer input transfer function in a three-layered human body is calculated by the numerical finite-difference time domain method. The examples for different radiometer input parameters and measurement methods are calculated and examined by experiment. The results of numerical modelling are applied for design of a 4.5 GHz microwave radiometer for breast cancer detection.
采用时域有限差分数值方法计算了辐射计输入传递函数在三层人体中的空间分布。对不同辐射计输入参数和测量方法的实例进行了计算和实验验证。将数值模拟结果应用于4.5 GHz乳腺癌微波辐射计的设计。
{"title":"Calculation of microwave radiometric signal in multilayered biological tissue","authors":"H. Hinrikus, J. Krasavin, K. Beilenhoff, H. Hartnagel","doi":"10.1109/IEMBS.1995.579840","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.579840","url":null,"abstract":"A spatial distribution of radiometer input transfer function in a three-layered human body is calculated by the numerical finite-difference time domain method. The examples for different radiometer input parameters and measurement methods are calculated and examined by experiment. The results of numerical modelling are applied for design of a 4.5 GHz microwave radiometer for breast cancer detection.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72776846","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
ANIA: a tool for angiographic image analysis and study ANIA:用于血管造影图像分析和研究的工具
A. La Cruz, G. Morinelli, P. Windyga, G. Bevilacqua, J. Silva
The main reason for lumen reduction of the arteries is lipid accumulation in their walls. Diagnosis of this disease is possible by the application of image analysis techniques. A tridimensional representation of the coronaries (arteries that perfuse the heart muscle) is needed for their precise evaluation. The present research proposes a tool to evaluate 2D and 3D processing algorithms from angiographic images. ANIA (Angiographic Image Analyzer) is developed on a Silicon Graphics platform, in Object Oriented Programming, and represents an alternative tool for improving the study of the coronaries.
动脉腔缩小的主要原因是动脉壁的脂质积聚。这种疾病的诊断是可能的应用图像分析技术。冠状动脉(灌注心肌的动脉)的三维表示需要精确的评估。本研究提出了一种评估血管造影图像的二维和三维处理算法的工具。ANIA(血管造影图像分析仪)是在面向对象编程的硅图形平台上开发的,代表了改进冠状动脉研究的另一种工具。
{"title":"ANIA: a tool for angiographic image analysis and study","authors":"A. La Cruz, G. Morinelli, P. Windyga, G. Bevilacqua, J. Silva","doi":"10.1109/IEMBS.1995.575160","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575160","url":null,"abstract":"The main reason for lumen reduction of the arteries is lipid accumulation in their walls. Diagnosis of this disease is possible by the application of image analysis techniques. A tridimensional representation of the coronaries (arteries that perfuse the heart muscle) is needed for their precise evaluation. The present research proposes a tool to evaluate 2D and 3D processing algorithms from angiographic images. ANIA (Angiographic Image Analyzer) is developed on a Silicon Graphics platform, in Object Oriented Programming, and represents an alternative tool for improving the study of the coronaries.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73016113","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Noninvasive fiber optic measurement of carotid to radial apparent phase velocity in hypertensive subjects 无创光纤测量高血压患者颈动脉至桡动脉视相速度
J.K.-J. Li, D. Amory, M. Singh, R. McMahon, Ying Zhu, G. Drzewiecki, D. O'Hara
Foot-to-foot pulse wave velocity has been popularly used in the clinical assessment of the local elastic properties of arteries. The apparent phase velocity (c/sub app/) however contains considerable more information about vascular interaction. We investigated this latter noninvasively in normal and hypertensive subjects by means of a pair of matched fiber optic sensors applied to carotid and radial arteries. Results show that c/sub app/ is higher at low than at high frequencies and with larger amplitudes and oscillations in hypertensives.
足对足脉搏波速度已广泛用于临床评估动脉局部弹性特性。然而,视相速度(c/sub app/)包含了更多关于血管相互作用的信息。我们通过一对匹配的光纤传感器应用于颈动脉和桡动脉,在正常和高血压受试者中无创地研究了后者。结果表明,高血压患者c/sub app/在低频率时高于高频率,且具有较大的振幅和振荡。
{"title":"Noninvasive fiber optic measurement of carotid to radial apparent phase velocity in hypertensive subjects","authors":"J.K.-J. Li, D. Amory, M. Singh, R. McMahon, Ying Zhu, G. Drzewiecki, D. O'Hara","doi":"10.1109/IEMBS.1995.575015","DOIUrl":"https://doi.org/10.1109/IEMBS.1995.575015","url":null,"abstract":"Foot-to-foot pulse wave velocity has been popularly used in the clinical assessment of the local elastic properties of arteries. The apparent phase velocity (c/sub app/) however contains considerable more information about vascular interaction. We investigated this latter noninvasively in normal and hypertensive subjects by means of a pair of matched fiber optic sensors applied to carotid and radial arteries. Results show that c/sub app/ is higher at low than at high frequencies and with larger amplitudes and oscillations in hypertensives.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75398605","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1