Prototype low-cost portable electrocardiogram (ECG) based on Arduino-Uno with Bluetooth feature

William Jerrel Iskandar, Ibnu Roihan, R. Koestoer
{"title":"Prototype low-cost portable electrocardiogram (ECG) based on Arduino-Uno with Bluetooth feature","authors":"William Jerrel Iskandar, Ibnu Roihan, R. Koestoer","doi":"10.1063/1.5139392","DOIUrl":null,"url":null,"abstract":"World Health Organization (WHO) data stated that heart diseases cause 37% of deaths in Indonesia. In Indonesia, devices used to monitor the heart’s activity or electrocardiogram (ECG) are only owned by some big hospitals. With an Arduino microprocessor, a simple portable ECG with a function to read the heart’s condition could be made. The AD8232 sensor is the main device that is used to read the heartbeat by processing the voltage received from the electrodes attached to the body. Combination of Arduino-Uno and HC-05 FC-114 as a Bluetooth antenna, an ECG display could be seen on a smartphone’s monitor in real-time. An ECG simulator is used as an artificial heart activity to be used as a trial for the ECG portable’s performance from test results. ECG using the simulator can be delivered to the smartphone’s monitor by Bluetooth module with an accurate result that draws the real-time condition of the patients.World Health Organization (WHO) data stated that heart diseases cause 37% of deaths in Indonesia. In Indonesia, devices used to monitor the heart’s activity or electrocardiogram (ECG) are only owned by some big hospitals. With an Arduino microprocessor, a simple portable ECG with a function to read the heart’s condition could be made. The AD8232 sensor is the main device that is used to read the heartbeat by processing the voltage received from the electrodes attached to the body. Combination of Arduino-Uno and HC-05 FC-114 as a Bluetooth antenna, an ECG display could be seen on a smartphone’s monitor in real-time. An ECG simulator is used as an artificial heart activity to be used as a trial for the ECG portable’s performance from test results. ECG using the simulator can be delivered to the smartphone’s monitor by Bluetooth module with an accurate result that draws the real-time condition of the patients.","PeriodicalId":22239,"journal":{"name":"THE 4TH BIOMEDICAL ENGINEERING’S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, HEALTH, AND MEDICAL DEVICES: Proceedings of the International Symposium of Biomedical Engineering (ISBE) 2019","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"THE 4TH BIOMEDICAL ENGINEERING’S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, HEALTH, AND MEDICAL DEVICES: Proceedings of the International Symposium of Biomedical Engineering (ISBE) 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.5139392","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

World Health Organization (WHO) data stated that heart diseases cause 37% of deaths in Indonesia. In Indonesia, devices used to monitor the heart’s activity or electrocardiogram (ECG) are only owned by some big hospitals. With an Arduino microprocessor, a simple portable ECG with a function to read the heart’s condition could be made. The AD8232 sensor is the main device that is used to read the heartbeat by processing the voltage received from the electrodes attached to the body. Combination of Arduino-Uno and HC-05 FC-114 as a Bluetooth antenna, an ECG display could be seen on a smartphone’s monitor in real-time. An ECG simulator is used as an artificial heart activity to be used as a trial for the ECG portable’s performance from test results. ECG using the simulator can be delivered to the smartphone’s monitor by Bluetooth module with an accurate result that draws the real-time condition of the patients.World Health Organization (WHO) data stated that heart diseases cause 37% of deaths in Indonesia. In Indonesia, devices used to monitor the heart’s activity or electrocardiogram (ECG) are only owned by some big hospitals. With an Arduino microprocessor, a simple portable ECG with a function to read the heart’s condition could be made. The AD8232 sensor is the main device that is used to read the heartbeat by processing the voltage received from the electrodes attached to the body. Combination of Arduino-Uno and HC-05 FC-114 as a Bluetooth antenna, an ECG display could be seen on a smartphone’s monitor in real-time. An ECG simulator is used as an artificial heart activity to be used as a trial for the ECG portable’s performance from test results. ECG using the simulator can be delivered to the smartphone’s monitor by Bluetooth module with an accurate result that draws the real-time condition of the patients.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于Arduino-Uno的具有蓝牙功能的低成本便携式心电图样机
世界卫生组织(世卫组织)的数据表明,在印度尼西亚,心脏病导致37%的死亡。在印度尼西亚,用于监测心脏活动或心电图(ECG)的设备只有一些大医院拥有。利用Arduino微处理器,可以制作出具有读取心脏状况功能的简单便携式心电图。AD8232传感器是主要设备,通过处理从附着在身体上的电极接收的电压来读取心跳。结合Arduino-Uno和HC-05 FC-114作为蓝牙天线,可以在智能手机的监视器上实时看到心电显示。利用心电模拟器作为人工心脏活动,从测试结果中对便携式心电仪的性能进行试验。使用模拟器的心电图可以通过蓝牙模块传送到智能手机的监视器上,并得到准确的结果,绘制出患者的实时状况。世界卫生组织(世卫组织)的数据表明,在印度尼西亚,心脏病导致37%的死亡。在印度尼西亚,用于监测心脏活动或心电图(ECG)的设备只有一些大医院拥有。利用Arduino微处理器,可以制作出具有读取心脏状况功能的简单便携式心电图。AD8232传感器是主要设备,通过处理从附着在身体上的电极接收的电压来读取心跳。结合Arduino-Uno和HC-05 FC-114作为蓝牙天线,可以在智能手机的监视器上实时看到心电显示。利用心电模拟器作为人工心脏活动,从测试结果中对便携式心电仪的性能进行试验。使用模拟器的心电图可以通过蓝牙模块传送到智能手机的监视器上,并得到准确的结果,绘制出患者的实时状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of tools utilization monitoring system on labor-intensive manufacturing industries Topology optimization on geometry of 3D printed “Impulse RC Alien 4 Inch” racing quadcopter frame with polylactic acid material Design and analysis of regenerative shock absorber using ball screw mechanism for vehicle suspension Effect of Sundanese music on daytime sleep quality based on EEG signal Static analysis of an energy storage and return (ESAR) prosthetic foot
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1