Noninvasive continuous optoacoustic monitor of total hemoglobin concentration

H. Brecht, Y. Petrov, D. Prough, D. Deyo, O. Hartrumpf, R. Esenaliev
{"title":"Noninvasive continuous optoacoustic monitor of total hemoglobin concentration","authors":"H. Brecht, Y. Petrov, D. Prough, D. Deyo, O. Hartrumpf, R. Esenaliev","doi":"10.1109/IEMBS.2002.1053286","DOIUrl":null,"url":null,"abstract":"During surgery associated with rapid blood loss, rapid fluid administration and transfusion of packed red blood cells, measurement of total hemoglobin concentration provides necessary information to direct decisions regarding transfusion. However, measurement of total hemoglobin concentration currently requires collection of a blood sample and either transport to a laboratory or centrifugation at the bedside. Recently we proposed to use optoacoustic technique for noninvasive and continuous monitoring of total hemoglobin concentration. High resolution of the optoacoustic technique may provide accurate measurement of total hemoglobin concentration by detecting and analyzing optoacoustic signals induced by short optical pulses in blood circulating in arteries or veins. We designed, built, and tested in vitro and in preliminary in vivo experiments a portable optoacoustic system for monitoring of total hemoglobin concentration in the radial artery. The system includes a nanosecond laser operating in the near-IR spectral range and a sensitive optoacoustic probe designed for irradiating the radial artery through the skin and detecting optoacoustic signals induced in blood. Results of our studies indicate that parameters of optoacoustic waves induced in blood are dependent on total hemoglobin concentration. The data suggest that the optoacoustic system may be used for accurate, noninvasive, and continuous monitoring of total hemoglobin concentration.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":"118 1","pages":"2289-2290 vol.3"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1053286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

During surgery associated with rapid blood loss, rapid fluid administration and transfusion of packed red blood cells, measurement of total hemoglobin concentration provides necessary information to direct decisions regarding transfusion. However, measurement of total hemoglobin concentration currently requires collection of a blood sample and either transport to a laboratory or centrifugation at the bedside. Recently we proposed to use optoacoustic technique for noninvasive and continuous monitoring of total hemoglobin concentration. High resolution of the optoacoustic technique may provide accurate measurement of total hemoglobin concentration by detecting and analyzing optoacoustic signals induced by short optical pulses in blood circulating in arteries or veins. We designed, built, and tested in vitro and in preliminary in vivo experiments a portable optoacoustic system for monitoring of total hemoglobin concentration in the radial artery. The system includes a nanosecond laser operating in the near-IR spectral range and a sensitive optoacoustic probe designed for irradiating the radial artery through the skin and detecting optoacoustic signals induced in blood. Results of our studies indicate that parameters of optoacoustic waves induced in blood are dependent on total hemoglobin concentration. The data suggest that the optoacoustic system may be used for accurate, noninvasive, and continuous monitoring of total hemoglobin concentration.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
总血红蛋白浓度无创连续光声监测
在与快速失血、快速给液和填充红细胞输血相关的手术中,总血红蛋白浓度的测量为指导输血决策提供了必要的信息。然而,目前总血红蛋白浓度的测量需要采集血液样本,然后运送到实验室或在床边进行离心。近年来,我们提出利用光声技术无创、连续监测总血红蛋白浓度。高分辨率的光声技术可以通过检测和分析动脉或静脉血液循环中由短光脉冲引起的光声信号,提供准确的总血红蛋白浓度测量。我们设计、建造并在体外和初步体内实验中测试了一种便携式光声系统,用于监测桡动脉中总血红蛋白浓度。该系统包括一个在近红外光谱范围内工作的纳秒激光和一个灵敏的光声探头,用于通过皮肤照射桡动脉并检测血液中诱导的光声信号。我们的研究结果表明,光声波在血液中诱导的参数依赖于总血红蛋白浓度。这些数据表明,光声系统可用于准确、无创和连续监测总血红蛋白浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
368
期刊最新文献
Contour extraction of fetus' head from echocardiogram using Snakes Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems Left ventricular volume changes after defibrillation Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT Comparative in vivo and ex vivo pacing and sensing performance study using isolated four-chamber working swine heart model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1