The effect of shock absorbing prosthetic components on the gaits of persons with lower-extremity amputations

S. Gard, Regina J. Konz
{"title":"The effect of shock absorbing prosthetic components on the gaits of persons with lower-extremity amputations","authors":"S. Gard, Regina J. Konz","doi":"10.1109/IEMBS.2002.1053339","DOIUrl":null,"url":null,"abstract":"Shock absorbing pylons (SAPs) are components that increase prosthetic compliance and provide shock absorption during walking, running, and other high-impact activities in persons with leg amputations. The purpose of this study was to investigate the effect of SAPs on the gaits of persons who walk with trans-tibial prostheses. Two gait analyses were performed on ten subjects walking with and without an Endolite TT (Telescopic-Torsion) Pylon. Comparison of kinematic and kinetic gait parameters indicated that there were few quantitative changes in the way people walked with and without the SAPs. The most consistent change among subjects was a reduction In the magnitude of an isolated force transient that occurred during the prosthetic loading response phase, an effect that was more evident at higher walking speeds. Results from a questionnaire that was administered to subjects indicated they generally preferred walking with the SAP for reasons related to comfort. We conclude that SAPs may provide significant benefit for persons with trans-tibial amputations who are able to routinely walk at speeds above approximately 1.3 m/sec.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":"33 1","pages":"2393-2394 vol.3"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1053339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Shock absorbing pylons (SAPs) are components that increase prosthetic compliance and provide shock absorption during walking, running, and other high-impact activities in persons with leg amputations. The purpose of this study was to investigate the effect of SAPs on the gaits of persons who walk with trans-tibial prostheses. Two gait analyses were performed on ten subjects walking with and without an Endolite TT (Telescopic-Torsion) Pylon. Comparison of kinematic and kinetic gait parameters indicated that there were few quantitative changes in the way people walked with and without the SAPs. The most consistent change among subjects was a reduction In the magnitude of an isolated force transient that occurred during the prosthetic loading response phase, an effect that was more evident at higher walking speeds. Results from a questionnaire that was administered to subjects indicated they generally preferred walking with the SAP for reasons related to comfort. We conclude that SAPs may provide significant benefit for persons with trans-tibial amputations who are able to routinely walk at speeds above approximately 1.3 m/sec.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
减震假体对下肢截肢者步态的影响
减震塔(sap)是增加假肢顺应性的组件,并在截肢者行走,跑步和其他高冲击活动中提供减震。本研究的目的是探讨SAPs对经胫骨假体行走的人的步态的影响。对10名受试者进行了两次步态分析,分别使用和不使用Endolite TT(伸缩-扭转)吊架。运动学和动力学步态参数的比较表明,在有和没有sap的情况下,人们的行走方式几乎没有定量变化。受试者之间最一致的变化是在假肢加载反应阶段发生的短暂孤立力的大小减少,这种效果在更高的行走速度下更为明显。对受试者进行问卷调查的结果表明,由于与舒适有关的原因,他们通常更喜欢使用SAP行走。我们得出的结论是,SAPs可以为能够以大约1.3米/秒的速度正常行走的胫骨截肢患者提供显著的益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
368
期刊最新文献
Contour extraction of fetus' head from echocardiogram using Snakes Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems Left ventricular volume changes after defibrillation Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT Comparative in vivo and ex vivo pacing and sensing performance study using isolated four-chamber working swine heart model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1