Quantitative elemental imaging with neutrons for breast cancer diagnosis: A GEANT4 study

A. Kapadia, J. Shah, G. Agasthya
{"title":"Quantitative elemental imaging with neutrons for breast cancer diagnosis: A GEANT4 study","authors":"A. Kapadia, J. Shah, G. Agasthya","doi":"10.1109/NSSMIC.2010.5874363","DOIUrl":null,"url":null,"abstract":"Neutron stimulated emission computed tomography (NSECT) has been proposed as an early cancer-detection technique with the capability of 3-D tomographic imaging for identification of malignant tumors. In previous work we have demonstrated the ability of the technique to differentiate between normal and malignant breast tumors based on the concentration of cancer-marking elements in the tissue. Here we present tomographic images from a breast phantom with benign and malignant tumors simulated in GEANT4. A simulated model of the NSECT system was developed in GEANT4, along with phantoms corresponding to the human breast with benign and malignant tumors. Each tumor within the breast was given a different concentration of cancer-marking trace elements based on values reported in literature. The phantom was scanned with a 5-MeV neutron beam over a 180-degree angle. Tomographic images were reconstructed for six elements of interest from 10 different spectral lines. The results showed excellent agreement between the location of the tumor and the concentration of trace element detected in gamma lines from bromine, cesium, sodium and zinc. These results demonstrate the ability of NSECT in quantitative elemental imaging for breast cancer detection.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"8 1","pages":"3065-3068"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Neutron stimulated emission computed tomography (NSECT) has been proposed as an early cancer-detection technique with the capability of 3-D tomographic imaging for identification of malignant tumors. In previous work we have demonstrated the ability of the technique to differentiate between normal and malignant breast tumors based on the concentration of cancer-marking elements in the tissue. Here we present tomographic images from a breast phantom with benign and malignant tumors simulated in GEANT4. A simulated model of the NSECT system was developed in GEANT4, along with phantoms corresponding to the human breast with benign and malignant tumors. Each tumor within the breast was given a different concentration of cancer-marking trace elements based on values reported in literature. The phantom was scanned with a 5-MeV neutron beam over a 180-degree angle. Tomographic images were reconstructed for six elements of interest from 10 different spectral lines. The results showed excellent agreement between the location of the tumor and the concentration of trace element detected in gamma lines from bromine, cesium, sodium and zinc. These results demonstrate the ability of NSECT in quantitative elemental imaging for breast cancer detection.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
中子定量元素成像诊断乳腺癌:一项GEANT4研究
中子激发发射计算机断层扫描(NSECT)已被提出作为一种早期癌症检测技术,具有识别恶性肿瘤的三维断层成像能力。在之前的工作中,我们已经证明了该技术能够根据组织中癌症标记元素的浓度来区分正常和恶性乳腺肿瘤。在这里,我们展示了GEANT4模拟的乳腺幻影的良性和恶性肿瘤的断层图像。在GEANT4中开发了NSECT系统的模拟模型,以及与人类乳腺良性肿瘤和恶性肿瘤相对应的幻影。根据文献报道的数值,给予乳腺内的每个肿瘤不同浓度的癌症标记微量元素。用5兆电子伏特的中子束以180度角扫描幻体。对来自10条不同谱线的6个感兴趣元素的层析图像进行了重建。结果表明,肿瘤的位置与伽玛线中微量元素的浓度(溴、铯、钠和锌)具有良好的一致性。这些结果证明了NSECT在乳腺癌定量元素成像检测中的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
CaF2(Eu): An “Old” scintillator revisited Evaluation of the accuracy and robustness of a motion correction algorithm for PET using a novel phantom approach The performance of GridPix detectors Applying the neutron scatter camera to treaty verification and warhead monitoring Development of an 8-channel time based readout ASIC for PET applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1