A fully integrated hepatitis B virus DNA detection SoC based on monolithic polysilicon nanowire CMOS process

Che-Wei Huang, Yu-Jie Huang, Pei-Wen Yen, Hsiao-Ting Hsueh, Chia-Yi Lin, Min-Cheng Chen, C. Ho, Fu-Liang Yang, H. Tsai, H. Liao, Y. Juang, Chorng-Kuang Wang, Chih-Ting Lin, Shey-Shi Lu
{"title":"A fully integrated hepatitis B virus DNA detection SoC based on monolithic polysilicon nanowire CMOS process","authors":"Che-Wei Huang, Yu-Jie Huang, Pei-Wen Yen, Hsiao-Ting Hsueh, Chia-Yi Lin, Min-Cheng Chen, C. Ho, Fu-Liang Yang, H. Tsai, H. Liao, Y. Juang, Chorng-Kuang Wang, Chih-Ting Lin, Shey-Shi Lu","doi":"10.1109/VLSIC.2012.6243821","DOIUrl":null,"url":null,"abstract":"Polysilicon nanowire (poly-Si NW) based biosensor is integrated with the wireless acquisition circuits in a standard CMOS SoC for the first time. To improve detection quality, a chopper DDA-based analog front-end with features of low noise, high CMRR, and rail-to-rail input range is implemented. Additional temperature sensor is also included to compensate temperature drift of the biosensor. The results indicate that the detection limit is as low as 10fM. The capability to distinguish one base-pair mismatched DNAs is also demonstrated.","PeriodicalId":6347,"journal":{"name":"2012 Symposium on VLSI Circuits (VLSIC)","volume":"78 2 1","pages":"124-125"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Symposium on VLSI Circuits (VLSIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSIC.2012.6243821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Polysilicon nanowire (poly-Si NW) based biosensor is integrated with the wireless acquisition circuits in a standard CMOS SoC for the first time. To improve detection quality, a chopper DDA-based analog front-end with features of low noise, high CMRR, and rail-to-rail input range is implemented. Additional temperature sensor is also included to compensate temperature drift of the biosensor. The results indicate that the detection limit is as low as 10fM. The capability to distinguish one base-pair mismatched DNAs is also demonstrated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于单片多晶硅纳米线CMOS工艺的全集成乙型肝炎病毒DNA检测SoC
基于多晶硅纳米线(poly-Si NW)的生物传感器首次与无线采集电路集成在标准CMOS SoC中。为了提高检测质量,实现了一种低噪声、高CMRR、轨对轨输入范围的斩波数模模拟前端。还包括额外的温度传感器,以补偿生物传感器的温度漂移。结果表明,检测限低至10fM。还证明了区分碱基对错配dna的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 635pW battery voltage supervisory circuit for miniature sensor nodes A −70dBm-sensitivity 522Mbps 0.19nJ/bit-TX 0.43nJ/bit-RX transceiver for TransferJet™ SoC in 65nm CMOS A 21.5mW 10+Gb/s mm-Wave phased-array transmitter in 65nm CMOS Design of a 2.5-GHz, 3-ps jitter, 8-locking-cycle, all-digital delay-locked loop with cycle-by-cycle phase adjustment A sub-100µW multi-functional cardiac signal processor for mobile healthcare applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1