BIOSENSOR FOR THE ENANTIOSELECTIVE ANALYSIS OF THE THYROID HORMONES (+)-3,3′,5-TRIIODO-L-THYRONINE (T3) AND (+)-3,3′,5,5′-TETRAIODO-L-THYRONINE (T4)

H. Aboul‐Enein, Stefan Raluca-Ioana, S. Lițescu, G. Radu
{"title":"BIOSENSOR FOR THE ENANTIOSELECTIVE ANALYSIS OF THE THYROID HORMONES (+)-3,3′,5-TRIIODO-L-THYRONINE (T3) AND (+)-3,3′,5,5′-TETRAIODO-L-THYRONINE (T4)","authors":"H. Aboul‐Enein, Stefan Raluca-Ioana, S. Lițescu, G. Radu","doi":"10.1081/IAS-120003660","DOIUrl":null,"url":null,"abstract":"ABSTRACT An amperometric biosensor based on L-aminoacid oxidase is proposed for enantioselective assay of (+)-3,3′,5-triiodo-L-thyronine (L-T3) and (+)-3,3′,5,5′-tetraiodo-L-thyronine (L-T4), due to the fact that only the L enantiomer has the hormonal activity. The construction of the amperometric biosensor is simple and reproducible. The analytical information obtained from enantioselective analysis are reliable. The RSD <1% assured by using the amperometric biosensors for L enantiomers assay as raw materials, and from tablets, demonstrated their suitability for the analysis of T3 and T4 at ppb concentration levels.","PeriodicalId":15987,"journal":{"name":"Journal of Immunoassay and Immunochemistry","volume":"600 1","pages":"181 - 190"},"PeriodicalIF":0.0000,"publicationDate":"2002-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Immunoassay and Immunochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/IAS-120003660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

ABSTRACT An amperometric biosensor based on L-aminoacid oxidase is proposed for enantioselective assay of (+)-3,3′,5-triiodo-L-thyronine (L-T3) and (+)-3,3′,5,5′-tetraiodo-L-thyronine (L-T4), due to the fact that only the L enantiomer has the hormonal activity. The construction of the amperometric biosensor is simple and reproducible. The analytical information obtained from enantioselective analysis are reliable. The RSD <1% assured by using the amperometric biosensors for L enantiomers assay as raw materials, and from tablets, demonstrated their suitability for the analysis of T3 and T4 at ppb concentration levels.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于对映选择性分析甲状腺激素(+)-3,3 ',5-三碘- 1 -甲状腺原氨酸(t3)和(+)-3,3 ',5,5 ' -四碘- 1 -甲状腺原氨酸(t4)的生物传感器
摘要:由于只有L对映体具有激素活性,提出了一种基于L-氨基酸氧化酶的电流型生物传感器,用于(+)-3,3 ',5-三碘-L-甲状腺原氨酸(L- t3)和(+)-3,3 ',5,5 ' -四碘-L-甲状腺原氨酸(L- t4)的对映选择性测定。该安培型生物传感器结构简单,重复性好。对映选择分析得到的分析信息是可靠的。以L对映体测定为原料的安培生物传感器和片剂的RSD均<1%,证明其适用于ppb浓度水平下的T3和T4的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modulation of acute stress and immune response in tilapia, Oreochromis niloticus, using longevity spinach, Gynura procumbens extract, as nutraceuticals Survey of the association between polymorphisms of CTLA-4 exon 1 49 A/G genes with rheumatoid arthritis in Iran Winner of the 2021 Journal of Immunoassay & Immunochemistry Early Career Research Prize Evidence of hepatitis B infection and co-infection with enteric fever among febrile patients in a primary health facility in Kogi State, Nigeria Medullary thyroid carcinoma diagnosed with liquid-based cytology and immunocytochemistry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1