Effect of repeated impulses on OIP

S. Balaji, L. Lavanya, S. Usa
{"title":"Effect of repeated impulses on OIP","authors":"S. Balaji, L. Lavanya, S. Usa","doi":"10.1109/ICHVE.2012.6357044","DOIUrl":null,"url":null,"abstract":"Oil impregnated cellulose paper (OIP) constitute major insulation of transformer windings. The cellulose insulation determines the lifespan of a transformer. Many of the transformer failures are mainly due to frequent application of over-voltages. It is necessary to analyze the degradation of OIP with respect to time interval between the impulse overvoltages. Cellulose degradation is usually characterized in terms of scission fraction which is given by degree of polymerization (DP). In this paper, an attempt has been made to analyze the degradation of OIP for different impulse voltages and time interval between the successive impulse voltages. Detailed experimental analyses are carried out for impulse overvoltages of 1.2/50μs, 0.4/50μs and 0.064/50μs by maintaining the time interval of 1 second, 3 seconds and 5 seconds between the successive impulses.","PeriodicalId":6375,"journal":{"name":"2012 International Conference on High Voltage Engineering and Application","volume":"1 1","pages":"558-561"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2012.6357044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Oil impregnated cellulose paper (OIP) constitute major insulation of transformer windings. The cellulose insulation determines the lifespan of a transformer. Many of the transformer failures are mainly due to frequent application of over-voltages. It is necessary to analyze the degradation of OIP with respect to time interval between the impulse overvoltages. Cellulose degradation is usually characterized in terms of scission fraction which is given by degree of polymerization (DP). In this paper, an attempt has been made to analyze the degradation of OIP for different impulse voltages and time interval between the successive impulse voltages. Detailed experimental analyses are carried out for impulse overvoltages of 1.2/50μs, 0.4/50μs and 0.064/50μs by maintaining the time interval of 1 second, 3 seconds and 5 seconds between the successive impulses.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
重复脉冲对OIP的影响
油浸纤维素纸(OIP)是变压器绕组的主要绝缘材料。纤维素绝缘决定了变压器的寿命。许多变压器故障主要是由于频繁使用过电压引起的。有必要分析脉冲过电压之间的时间间隔对OIP退化的影响。纤维素的降解通常用聚合度(DP)给出的裂解分数来表征。本文试图分析不同冲击电压和连续冲击电压间隔时间下OIP的退化情况。对脉冲过电压分别为1.2/50μs、0.4/50μs和0.064/50μs时,连续脉冲的时间间隔分别为1秒、3秒和5秒进行了详细的实验分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of SiO2 particles on surface charge of epoxy nanocomposites The properties of space charge in oil-paper insulation during electrical-thermal aging A study of validation of condition monitoring method of NPPs cable through volume electrical resistivity Ice adhesion on the surface of PDMS/nano-silica hybrid super-hydrophobic coating Sensitivity study on streaming electrification of transformer liquids by using rotating disc method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1