Inter-Laboratory Reproducibility and Interchangeability of 3R4F and 1R6F Reference Cigarettes in Mainstream Smoke Chemical Analysis and In Vitro Toxicity Assays
Y. Sakai, Sakura Mori, Miyuki Yanagimachi, Tomohiro Takahashi, K. Shibuya, Asami Kumagai, S. Ishikawa, S. Ito, Toshiro Fukushima
{"title":"Inter-Laboratory Reproducibility and Interchangeability of 3R4F and 1R6F Reference Cigarettes in Mainstream Smoke Chemical Analysis and In Vitro Toxicity Assays","authors":"Y. Sakai, Sakura Mori, Miyuki Yanagimachi, Tomohiro Takahashi, K. Shibuya, Asami Kumagai, S. Ishikawa, S. Ito, Toshiro Fukushima","doi":"10.2478/cttr-2020-0011","DOIUrl":null,"url":null,"abstract":"Summary A new reference cigarette, 1R6F, produced by the Kentucky Tobacco Research and Development Center, has been manufactured as a substitute for the 3R4F reference cigarette because of a depletion of 3R4F stock. The purpose of the current study was to investigate the interchangeability of 1R6F and 3R4F by comparing the chemical and biological characteristics of the mainstream smoke and to assess the inter-laboratory reproducibility by comparing the results obtained in the current study with a previous report. We analyzed 45 priority chemicals required by Health Canada for regulatory reporting and assessed the toxicological effects of cigarette smoke using in vitro standard toxicological assays recommended by the Cooperation Centre for Scientific Research Relative to Tobacco (CORESTA) under the International Organization for Standardization (ISO) standard and intense smoking regimens. The results of the chemical analysis and standard toxicological assays showed a good inter-laboratory reproducibility for 1R6F as a reference cigarette, while there were some slight reproducible differences between 1R6F and 3R4F. In addition, we investigated the interchangeability of 1R6F with 3R4F in some additional toxicological assays that detect oxidative stress because oxidative stress is a principle endpoint used in tobacco research with next generation tobacco and nicotine delivery products (NGPs). Both 1R6F and 3R4F elicited comparable responses in the oxidative stress assays. Overall, our results showed inter-laboratory reproducibility in chemical and standard toxicological assessments of 1R6F; thus, suggesting the suitability of 1R6F as a reference cigarette. In addition, the results obtained in the oxidative stress assays provide insight into the interchangeability of 1R6F with 3R4F when used as a comparator for NGPs.","PeriodicalId":10723,"journal":{"name":"Contributions to Tobacco & Nicotine Research","volume":"358 1","pages":"119 - 135"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contributions to Tobacco & Nicotine Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/cttr-2020-0011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Summary A new reference cigarette, 1R6F, produced by the Kentucky Tobacco Research and Development Center, has been manufactured as a substitute for the 3R4F reference cigarette because of a depletion of 3R4F stock. The purpose of the current study was to investigate the interchangeability of 1R6F and 3R4F by comparing the chemical and biological characteristics of the mainstream smoke and to assess the inter-laboratory reproducibility by comparing the results obtained in the current study with a previous report. We analyzed 45 priority chemicals required by Health Canada for regulatory reporting and assessed the toxicological effects of cigarette smoke using in vitro standard toxicological assays recommended by the Cooperation Centre for Scientific Research Relative to Tobacco (CORESTA) under the International Organization for Standardization (ISO) standard and intense smoking regimens. The results of the chemical analysis and standard toxicological assays showed a good inter-laboratory reproducibility for 1R6F as a reference cigarette, while there were some slight reproducible differences between 1R6F and 3R4F. In addition, we investigated the interchangeability of 1R6F with 3R4F in some additional toxicological assays that detect oxidative stress because oxidative stress is a principle endpoint used in tobacco research with next generation tobacco and nicotine delivery products (NGPs). Both 1R6F and 3R4F elicited comparable responses in the oxidative stress assays. Overall, our results showed inter-laboratory reproducibility in chemical and standard toxicological assessments of 1R6F; thus, suggesting the suitability of 1R6F as a reference cigarette. In addition, the results obtained in the oxidative stress assays provide insight into the interchangeability of 1R6F with 3R4F when used as a comparator for NGPs.