A. Grinek, I. Boychuk, D. Tinyakov, N. Marchenko, S. Aleksyanc, E. Slonov
{"title":"DEVICE FOR MONITORING ADDITIONAL LOSSES OF A SHIP TRANSFORMER BASED ON A TEMPERATURE MODEL","authors":"A. Grinek, I. Boychuk, D. Tinyakov, N. Marchenko, S. Aleksyanc, E. Slonov","doi":"10.34046/aumsuomt105/34","DOIUrl":null,"url":null,"abstract":"The article considers a way to improve the efficiency of ship transformers. A temperature control system is \nused. In the process of changing the voltage in the ship's system, thermal losses of copper in the iron core and \ncoil usually often occur. Thus, overloading will cause excessive heating and may affect the operation of the \ntransformer. The calculation of the thermal parameters of the transformer is given. The mathematical model in \nMatlab is shown. The article proposes a functional diagram of the device. The control system monitors the \ntemperature inside the transformer when operating under overload conditions. It is shown that the installation \nof the device will improve the performance o f the transformer and save its service life","PeriodicalId":19521,"journal":{"name":"Operation of Maritime Transport","volume":"42 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operation of Maritime Transport","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34046/aumsuomt105/34","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The article considers a way to improve the efficiency of ship transformers. A temperature control system is
used. In the process of changing the voltage in the ship's system, thermal losses of copper in the iron core and
coil usually often occur. Thus, overloading will cause excessive heating and may affect the operation of the
transformer. The calculation of the thermal parameters of the transformer is given. The mathematical model in
Matlab is shown. The article proposes a functional diagram of the device. The control system monitors the
temperature inside the transformer when operating under overload conditions. It is shown that the installation
of the device will improve the performance o f the transformer and save its service life