{"title":"Rapid Analysis of Maleic Hydrazide in Vegetables and Fruits Using Capillary Electrophoresis","authors":"Ritsuko Cho","doi":"10.3358/SHOKUEISHI.41.74","DOIUrl":null,"url":null,"abstract":"A rapid analytical method was developed for determination of maleic hydrazide in agricultural products by using capillary electrophoresis (CE). A sample was homogenized and extracted with water. The extract was purified with Sep-Pak C18 and evaporated. The residue was dissolved in water and filtered through a 0.20μm membrane filter. The sample solution thus prepared was subjected to CE using 0.02mol/L borate buffer pH 10.0-glycerine (95:5) as the running buffer. Detection was achieved with a UV detector set at 330nm.The recoveries of maleic hydrazide from 8 kinds of vegetables and fruits spiked at the levels of 2ppm and 20ppm were 76.7-104.3% and 92.4-103.2%, respectively. The detection limit of maleic hydrazide was 1ppm. This method was not applicable to citrus fruits except for satsuma mandarins.","PeriodicalId":17269,"journal":{"name":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3358/SHOKUEISHI.41.74","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
A rapid analytical method was developed for determination of maleic hydrazide in agricultural products by using capillary electrophoresis (CE). A sample was homogenized and extracted with water. The extract was purified with Sep-Pak C18 and evaporated. The residue was dissolved in water and filtered through a 0.20μm membrane filter. The sample solution thus prepared was subjected to CE using 0.02mol/L borate buffer pH 10.0-glycerine (95:5) as the running buffer. Detection was achieved with a UV detector set at 330nm.The recoveries of maleic hydrazide from 8 kinds of vegetables and fruits spiked at the levels of 2ppm and 20ppm were 76.7-104.3% and 92.4-103.2%, respectively. The detection limit of maleic hydrazide was 1ppm. This method was not applicable to citrus fruits except for satsuma mandarins.