Load frequency control of two area power system with AC-DC tie line using PSO optimized controller

N. Nagarjuna, G. Shankar
{"title":"Load frequency control of two area power system with AC-DC tie line using PSO optimized controller","authors":"N. Nagarjuna, G. Shankar","doi":"10.1109/ICPACE.2015.7274948","DOIUrl":null,"url":null,"abstract":"This paper presents the load frequency control(LFC) of two area interconnected power system each comprising of a thermal unit with reheat turbine and a hydro generating unit. In order to have better performance of LFC, proportional-integral-derivative(PID) controller is used whose parameters are optimized using particle swarm optimization (PSO) technique. In the present work, effect of AC-DC tie lie on the performance of LFC in two area power system using PSO tuned controllers is tested and compared with the performance of LFC with only AC tie line. It is observed that the transient performance of the system with parallel AC-DC tie line is improved when compared to the performance of the system with only AC tie line. The results obtained are compared and presented.","PeriodicalId":6644,"journal":{"name":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","volume":"41 1","pages":"227-231"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPACE.2015.7274948","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

This paper presents the load frequency control(LFC) of two area interconnected power system each comprising of a thermal unit with reheat turbine and a hydro generating unit. In order to have better performance of LFC, proportional-integral-derivative(PID) controller is used whose parameters are optimized using particle swarm optimization (PSO) technique. In the present work, effect of AC-DC tie lie on the performance of LFC in two area power system using PSO tuned controllers is tested and compared with the performance of LFC with only AC tie line. It is observed that the transient performance of the system with parallel AC-DC tie line is improved when compared to the performance of the system with only AC tie line. The results obtained are compared and presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用粒子群优化控制器对交直流并线两区电力系统的负荷频率进行控制
本文介绍了由一个带再热水轮机的热力机组和一个水轮发电机组组成的两个区域互联电力系统的负荷频率控制。为了使LFC具有更好的性能,采用比例-积分-导数(PID)控制器,并采用粒子群优化(PSO)技术对其参数进行优化。在本工作中,测试了采用PSO调谐控制器的两区电力系统中,交直流电压对LFC性能的影响,并与仅使用交流电压的LFC性能进行了比较。结果表明,并联交直流联络线对系统暂态性能的影响比单交联络线对系统暂态性能的影响要大。并对所得结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Asset management in smart grids using improved Dissolved Gas Analysis PLC based intelligent power factor correctors for industrial power systems-A case study A multiple environment dispatch problem solution using ant colony optimization for micro-grids Modeling, simulation and comparative study of new compound alloy based P-I-N solar cells - An efficient way of energy management Modeling and analysis of 6 pulse rectifier used in HVDC link
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1