A 2-to-16GHz 204mW 3mm-resolution stepped-frequency radar for breast-cancer diagnostic imaging in 65nm CMOS

M. Caruso, M. Bassi, A. Bevilacqua, A. Neviani
{"title":"A 2-to-16GHz 204mW 3mm-resolution stepped-frequency radar for breast-cancer diagnostic imaging in 65nm CMOS","authors":"M. Caruso, M. Bassi, A. Bevilacqua, A. Neviani","doi":"10.1109/ISSCC.2013.6487717","DOIUrl":null,"url":null,"abstract":"Radar imaging is gaining interest for medical, security, and industrial applications. Enabled by the advances in silicon technologies, a clear trend towards higher integration is observed [1-3]. Early-stage breast cancer detection is a promising application for radar imaging, as first clinical trials with patients have been carried out [4]. Commercial VNAs have been used in these experiments, but custom hardware is needed to improve the sensitivity, and to decrease the size and the cost of the setup [4]. Medical radar imaging sets great challenges. The radiation must be coupled into the body, while the skin acts as a shield. The waves that penetrate beyond the skin are heavily attenuated (>80dB for a few centimeters at 10GHz [4]). Tumor cells have different electrical properties than the healthy tissue, thus reflecting the waves and allowing for detection; this contrast is frequency dependent, decreasing at higher frequencies. These fundamental limits result in a radar requiring a dynamic range in excess to 100dB [4], and force operation in the lower-GHz range. In contrast, mm-Waves would be preferred to achieve higher resolution [1]. Ultra-wideband radars combine larger scattered energy collected at lower frequencies (thus higher SNR), and mm-range resolution, since the resolution is set by the overall bandwidth and the antenna array arrangement [2].","PeriodicalId":6378,"journal":{"name":"2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers","volume":"77 1","pages":"240-241"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSCC.2013.6487717","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Radar imaging is gaining interest for medical, security, and industrial applications. Enabled by the advances in silicon technologies, a clear trend towards higher integration is observed [1-3]. Early-stage breast cancer detection is a promising application for radar imaging, as first clinical trials with patients have been carried out [4]. Commercial VNAs have been used in these experiments, but custom hardware is needed to improve the sensitivity, and to decrease the size and the cost of the setup [4]. Medical radar imaging sets great challenges. The radiation must be coupled into the body, while the skin acts as a shield. The waves that penetrate beyond the skin are heavily attenuated (>80dB for a few centimeters at 10GHz [4]). Tumor cells have different electrical properties than the healthy tissue, thus reflecting the waves and allowing for detection; this contrast is frequency dependent, decreasing at higher frequencies. These fundamental limits result in a radar requiring a dynamic range in excess to 100dB [4], and force operation in the lower-GHz range. In contrast, mm-Waves would be preferred to achieve higher resolution [1]. Ultra-wideband radars combine larger scattered energy collected at lower frequencies (thus higher SNR), and mm-range resolution, since the resolution is set by the overall bandwidth and the antenna array arrangement [2].
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于乳腺癌诊断成像的2- 16ghz 204mW 3mm分辨率65纳米CMOS雷达
雷达成像在医疗、安全和工业应用中越来越受到关注。在硅技术进步的推动下,观察到一个明显的更高集成度的趋势[1-3]。早期乳腺癌的检测是雷达成像的一个很有前途的应用,因为首次临床试验已经在患者中进行。商用vna已用于这些实验,但需要定制硬件来提高灵敏度,并减少安装[4]的尺寸和成本。医学雷达成像面临着巨大的挑战。辐射必须耦合到体内,而皮肤则起到屏蔽作用。穿透皮肤以外的电波被严重衰减(在10GHz波段,几厘米衰减80dB)。肿瘤细胞具有与健康组织不同的电特性,从而反射电波并允许检测;这种对比是频率相关的,在更高的频率下会降低。这些基本限制导致雷达需要超过100dB[4]的动态范围,并迫使其在较低ghz范围内工作。相比之下,毫米波将更倾向于获得更高的分辨率。超宽带雷达结合了在较低频率收集到的较大的散射能量(因此信噪比更高)和毫米距离分辨率,因为分辨率是由总带宽和天线阵列布置[2]决定的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A CMOS dual-switching power-supply modulator with 8% efficiency improvement for 20MHz LTE Envelope Tracking RF power amplifiers A 3.4pJ FeRAM-enabled D flip-flop in 0.13µm CMOS for nonvolatile processing in digital systems Razor-lite: A side-channel error-detection register for timing-margin recovery in 45nm SOI CMOS Self-super-cutoff power gating with state retention on a 0.3V 0.29fJ/cycle/gate 32b RISC core in 0.13µm CMOS A fully intraocular 0.0169mm2/pixel 512-channel self-calibrating epiretinal prosthesis in 65nm CMOS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1