{"title":"A 2-to-16GHz 204mW 3mm-resolution stepped-frequency radar for breast-cancer diagnostic imaging in 65nm CMOS","authors":"M. Caruso, M. Bassi, A. Bevilacqua, A. Neviani","doi":"10.1109/ISSCC.2013.6487717","DOIUrl":null,"url":null,"abstract":"Radar imaging is gaining interest for medical, security, and industrial applications. Enabled by the advances in silicon technologies, a clear trend towards higher integration is observed [1-3]. Early-stage breast cancer detection is a promising application for radar imaging, as first clinical trials with patients have been carried out [4]. Commercial VNAs have been used in these experiments, but custom hardware is needed to improve the sensitivity, and to decrease the size and the cost of the setup [4]. Medical radar imaging sets great challenges. The radiation must be coupled into the body, while the skin acts as a shield. The waves that penetrate beyond the skin are heavily attenuated (>80dB for a few centimeters at 10GHz [4]). Tumor cells have different electrical properties than the healthy tissue, thus reflecting the waves and allowing for detection; this contrast is frequency dependent, decreasing at higher frequencies. These fundamental limits result in a radar requiring a dynamic range in excess to 100dB [4], and force operation in the lower-GHz range. In contrast, mm-Waves would be preferred to achieve higher resolution [1]. Ultra-wideband radars combine larger scattered energy collected at lower frequencies (thus higher SNR), and mm-range resolution, since the resolution is set by the overall bandwidth and the antenna array arrangement [2].","PeriodicalId":6378,"journal":{"name":"2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers","volume":"77 1","pages":"240-241"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSCC.2013.6487717","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
Radar imaging is gaining interest for medical, security, and industrial applications. Enabled by the advances in silicon technologies, a clear trend towards higher integration is observed [1-3]. Early-stage breast cancer detection is a promising application for radar imaging, as first clinical trials with patients have been carried out [4]. Commercial VNAs have been used in these experiments, but custom hardware is needed to improve the sensitivity, and to decrease the size and the cost of the setup [4]. Medical radar imaging sets great challenges. The radiation must be coupled into the body, while the skin acts as a shield. The waves that penetrate beyond the skin are heavily attenuated (>80dB for a few centimeters at 10GHz [4]). Tumor cells have different electrical properties than the healthy tissue, thus reflecting the waves and allowing for detection; this contrast is frequency dependent, decreasing at higher frequencies. These fundamental limits result in a radar requiring a dynamic range in excess to 100dB [4], and force operation in the lower-GHz range. In contrast, mm-Waves would be preferred to achieve higher resolution [1]. Ultra-wideband radars combine larger scattered energy collected at lower frequencies (thus higher SNR), and mm-range resolution, since the resolution is set by the overall bandwidth and the antenna array arrangement [2].