Wavelet Signal Processing Tools for Quantifying and Monitoring the in-vitro Dissolution Profiles of Tenofovir Disoproxil Fumarate and Emtricitabine in Tablets
E. Dinç, N. Özdemir, Özgür Üstündağ, E. Büker, G. Tilkan, V. D. Hoang
{"title":"Wavelet Signal Processing Tools for Quantifying and Monitoring the in-vitro Dissolution Profiles of Tenofovir Disoproxil Fumarate and Emtricitabine in Tablets","authors":"E. Dinç, N. Özdemir, Özgür Üstündağ, E. Büker, G. Tilkan, V. D. Hoang","doi":"10.29356/jmcs.v66i4.1790","DOIUrl":null,"url":null,"abstract":"Abstract. Wavelet signal processing tools were applied to the UV spectral dataset for the quantification and understanding the in vitro dissolution behaviors of tenofovir disoproxil fumarate (TEN) and emtricitabine (EMT) in commercial tablets with low-cost and short analysis time. Preliminary signal analysis tests were staged to determine the most suitable wavelet family or families to monitor in vitro dissolution profiles and quantify the drugs of interest. Of these, Daubechies (db6), Symlets 3 (sym3), Biorthogonal 1.5 (bior1.5) and Coiflets 5 (coif5) continuous wavelet tools have been found to be optimal as they provide the desired results. Calibration curves obtained by regression analysis of the continuous wavelet signal (dependent variable) on concentration (independent variable) were found to be linear in the range of 4.0-52.0 µg/mL for both drugs. The validity of CWT signal processing tools was tested by analyzing mixtures made in the laboratory. The Quantitation of TEN and EMT by the proposed signal processing tools did not require a pre-separation procedure. They were successfully utilized for the assay and in vitro dissolution monitoring of the two drugs in their combined tablets. Consequently, the presented work provided alternative tools based on wavelet signal processing to traditional derivative spectrophotometry to resolve a two-component mixture without using a priori separation step. \n \nResumen. Las herramientas de transformada continua de wavelets fueron empleadas para el procesamiento de espectros de absorción UV con el fin de lograr la cuantificación y la comprensión del comportamiento de fumarato de disoproxilo de tenofovir (TEN) y de emtricitabina (EMT) en la disolución in vitro de las tabletas comerciales, con bajo costo y corto tiempo de análisis. Se realizaron pruebas preliminares de análisis de señales para determinar la familia o familias de ondículas más adecuadas para monitorear los perfiles de disolución in vitro y para cuantificar los fármacos de interés. Entre ellos, las herramientas Daubechies (db6), Symlets 3 (sym3), Biorthogonal 1.5 (bior1.5) y Coiflets 5 (coif5) resultaron ser óptimas proporcionando resultados deseados. Funciones de calibración obtenidas mediante el análisis de regresión de señales de ondículas transformadas (variable dependiente) obtenidas para soluciones de calibración (concentración - variable independiente) presentaron buena linealidad en el intervalo de concentraciones 4.0-52.0 µg/mL para ambos fármacos. La validez de procesamiento de señales CWT fue demostrada mediante el análisis de mezclas de conocidas concentraciones, preparadas en el laboratorio. La cuantificación de TEN y EMT no requiere su separación previa. El procedimiento fue empleado en el ensayo de monitoreo de la disolución in vitro de los fármacos y en las tabletas con contenían los dos fármacos. En este trabajo se propone un procedimiento basado en CWT, alternativo respecto a la tradicional espectrofotometría de derivadas para resolución de mezclas binarias sin necesidad de separación previa de dos componentes.","PeriodicalId":17377,"journal":{"name":"Journal of the Mexican Chemical Society","volume":"1 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mexican Chemical Society","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.29356/jmcs.v66i4.1790","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1
Abstract
Abstract. Wavelet signal processing tools were applied to the UV spectral dataset for the quantification and understanding the in vitro dissolution behaviors of tenofovir disoproxil fumarate (TEN) and emtricitabine (EMT) in commercial tablets with low-cost and short analysis time. Preliminary signal analysis tests were staged to determine the most suitable wavelet family or families to monitor in vitro dissolution profiles and quantify the drugs of interest. Of these, Daubechies (db6), Symlets 3 (sym3), Biorthogonal 1.5 (bior1.5) and Coiflets 5 (coif5) continuous wavelet tools have been found to be optimal as they provide the desired results. Calibration curves obtained by regression analysis of the continuous wavelet signal (dependent variable) on concentration (independent variable) were found to be linear in the range of 4.0-52.0 µg/mL for both drugs. The validity of CWT signal processing tools was tested by analyzing mixtures made in the laboratory. The Quantitation of TEN and EMT by the proposed signal processing tools did not require a pre-separation procedure. They were successfully utilized for the assay and in vitro dissolution monitoring of the two drugs in their combined tablets. Consequently, the presented work provided alternative tools based on wavelet signal processing to traditional derivative spectrophotometry to resolve a two-component mixture without using a priori separation step.
Resumen. Las herramientas de transformada continua de wavelets fueron empleadas para el procesamiento de espectros de absorción UV con el fin de lograr la cuantificación y la comprensión del comportamiento de fumarato de disoproxilo de tenofovir (TEN) y de emtricitabina (EMT) en la disolución in vitro de las tabletas comerciales, con bajo costo y corto tiempo de análisis. Se realizaron pruebas preliminares de análisis de señales para determinar la familia o familias de ondículas más adecuadas para monitorear los perfiles de disolución in vitro y para cuantificar los fármacos de interés. Entre ellos, las herramientas Daubechies (db6), Symlets 3 (sym3), Biorthogonal 1.5 (bior1.5) y Coiflets 5 (coif5) resultaron ser óptimas proporcionando resultados deseados. Funciones de calibración obtenidas mediante el análisis de regresión de señales de ondículas transformadas (variable dependiente) obtenidas para soluciones de calibración (concentración - variable independiente) presentaron buena linealidad en el intervalo de concentraciones 4.0-52.0 µg/mL para ambos fármacos. La validez de procesamiento de señales CWT fue demostrada mediante el análisis de mezclas de conocidas concentraciones, preparadas en el laboratorio. La cuantificación de TEN y EMT no requiere su separación previa. El procedimiento fue empleado en el ensayo de monitoreo de la disolución in vitro de los fármacos y en las tabletas con contenían los dos fármacos. En este trabajo se propone un procedimiento basado en CWT, alternativo respecto a la tradicional espectrofotometría de derivadas para resolución de mezclas binarias sin necesidad de separación previa de dos componentes.
摘要应用小波信号处理工具对紫外光谱数据进行定量分析,了解富马酸替诺福韦(TEN)和恩曲他滨(EMT)在市售片剂中的体外溶出行为,成本低,分析时间短。初步的信号分析测试阶段确定最合适的小波家族或家族来监测体外溶出谱和量化感兴趣的药物。其中,Daubechies (db6), Symlets 3 (sym3), Biorthogonal 1.5 (bior1.5)和Coiflets 5 (coif5)连续小波工具已被发现是最佳的,因为它们提供了所需的结果。两种药物的连续小波信号(因变量)与浓度(自变量)在4.0 ~ 52.0µg/mL范围内均呈线性关系。通过对实验室制作的混合物进行分析,验证了CWT信号处理工具的有效性。提出的信号处理工具的定量TEN和EMT不需要分离前程序。成功地应用于两药联合片剂的测定和体外溶出度监测。因此,提出的工作提供了基于小波信号处理的替代工具,以传统的导数分光光度法来解决双组分混合物,而不使用先验分离步骤。Resumen。Las herramentas de transformada continua de小波,fueron员工,para el过程,amiente de espectros absorción紫外线,el finente de lograr cuantificación y la comprensión, del comamiente de fucomente de替诺福韦(TEN)和emtricitabina (EMT) en la disolución,体外,de Las tabletas商业,con bajo cost y corto time de análisis。这一过程的初步实现是análisis de señales从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发,从确定的角度出发。Entre ello, las herramientas Daubechies (db6), Symlets 3 (sym3), Biorthogonal 1.5 (bior1.5) y Coiflets 5 (coif5) results on ser óptimas proporcionand do resultados deseados。functionones de calibración obtenidas mediante el análisis de regresión de señales de ondículas transformadas(变量依赖)obtenidas para soluciones de calibración (concentración -变量独立)介绍buena linealidad en el intervalo de concentraciones 4.0-52.0µg/mL para ambos fármacos。La validez de procesamiento de señales CWT fudemostrada mediante el análisis de mezclas de conocidas concentraciones,制备在实验室。La cuantificación de TEN y EMT不需要su separación previa。El procedimiento fue empleado en El ensayo de monitoreo de la disolucion体外de los farmacos y在拉斯维加斯tabletas con contenian洛杉矶dos farmacos。En este trabajo se proone unprocedimiento basado En CWT,相对于传统的espectrofotometría de derivative as para resolución de mezclas binarias sin necesidad de separación previa de dos components的替代方案。
期刊介绍:
The Journal of the Mexican Chemical Society (J. Mex. Chem. Soc.) is a scientific, blind, peer reviewed, and open access, free of charge publication that covers all areas of chemistry and its sub-disciplines (i.e. medicinal chemistry, natural products, electrochemistry, material science, computational chemistry, organic chemistry, bionirganic chemistry, etc). It is devoted to facilitating the worldwide advancement of our understanding of chemistry. It will primarily publish original contributions of research in all branches of the theory and practice of chemistry in its broadest context as well as critical reviews in active areas of chemical research where the author has published significant contribution. The J. Mex. Chem. Soc. is a quarterly publication which language of submission and publication is English. To be suitable for publication in J. Mex. Chem. Soc., manuscripts must describe novel aspects of chemistry, high quality of results and discussion an excellent bibliographic support, and contribute to the development of the field. Routine or incremental work are not suitable for publication in J. Mex. Chem. Soc. Authors are encouraged to send contributions in electronic form. Our online submission system guides you stepwise through the process of entering your article details and uploading your files.