Development of analytical method for simultaneous detection of 1-[(2- chlorophenyl) methyllimino methyl] cyclopentanol hydroclorid (CCM) and 2- Hydroxy-2- (o-chloro phenyl) cyclohexanon (HCH), two precursors of ketamine, in wastewater by LC-MS/MS
Thanh Vuong Tong Thi, Cuong Truong Manh, Truong Nguyen Xuan, Thuy Linh Nguyen Thi, Ngoc Lan Dang Thi, Thanh Ha Pham Thi, Ha Thai Tran Nguyen, Binh Vu Ngan
{"title":"Development of analytical method for simultaneous detection of 1-[(2- chlorophenyl) methyllimino methyl] cyclopentanol hydroclorid (CCM) and 2- Hydroxy-2- (o-chloro phenyl) cyclohexanon (HCH), two precursors of ketamine, in wastewater by LC-MS/MS","authors":"Thanh Vuong Tong Thi, Cuong Truong Manh, Truong Nguyen Xuan, Thuy Linh Nguyen Thi, Ngoc Lan Dang Thi, Thanh Ha Pham Thi, Ha Thai Tran Nguyen, Binh Vu Ngan","doi":"10.47866/2615-9252/vjfc.3964","DOIUrl":null,"url":null,"abstract":"Ketamin is a pharmaceutical compound that is abused as a narcotic drug, causing health problems for users. In controlling ketamine abuse, the detection of ketamine precursors can be a useful tool for tracing illegal ketamine production sites. In this study, an analytical method for determination of two ketamine precursors, 1-[(2-chlorophenyl) methyllimino methyl] cyclopentanol hydroclorid (CCM) and 2-Hydroxy-2- (o-chloro phenyl) cyclohexanon (HCH), in wastewater using solid phase extraction (SPE) and liquid chromatogrphy tandem mass spectrometry (LC-MS/MS) was developed and validated. An LC-MS/MS system employing a Zorbax C18 column (2.1 x 100 mm, 1.8 µm) and a mobile phase composing acetonitrile and water containing 0.1% (m/v) of formic acid in a gradient program at the flow rate of 0.3 mL/min and injection volume of 5 µL. The detection of analytes was done with electrospray ionization at positive mode (ESI+) employing multi reaction monitoring (MRM) at m/z of 238.5 and 225.5 for for CCM and HCH, respectively. The method was validated according to requirements of AOAC International and EC and was proved as reliable for intended use. ","PeriodicalId":12896,"journal":{"name":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","volume":"37 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47866/2615-9252/vjfc.3964","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Ketamin is a pharmaceutical compound that is abused as a narcotic drug, causing health problems for users. In controlling ketamine abuse, the detection of ketamine precursors can be a useful tool for tracing illegal ketamine production sites. In this study, an analytical method for determination of two ketamine precursors, 1-[(2-chlorophenyl) methyllimino methyl] cyclopentanol hydroclorid (CCM) and 2-Hydroxy-2- (o-chloro phenyl) cyclohexanon (HCH), in wastewater using solid phase extraction (SPE) and liquid chromatogrphy tandem mass spectrometry (LC-MS/MS) was developed and validated. An LC-MS/MS system employing a Zorbax C18 column (2.1 x 100 mm, 1.8 µm) and a mobile phase composing acetonitrile and water containing 0.1% (m/v) of formic acid in a gradient program at the flow rate of 0.3 mL/min and injection volume of 5 µL. The detection of analytes was done with electrospray ionization at positive mode (ESI+) employing multi reaction monitoring (MRM) at m/z of 238.5 and 225.5 for for CCM and HCH, respectively. The method was validated according to requirements of AOAC International and EC and was proved as reliable for intended use.