{"title":"Oxygen plasma treatment of sputtered TiO2 thin film for surface modification of PDMS","authors":"T. Maturos, A. Wisitsora-at, T. Lomas, A. Sappat, A. Tuantranont","doi":"10.1109/NANO.2007.4601331","DOIUrl":null,"url":null,"abstract":"We present the modification of polydimethylsiloxane (PDMS) surface by titanium dioxide (TiO2) thin film coating and subsequent oxygen plasma treatment. TiO2 thin film was deposited on the prepared PDMS samples by reactive dc sputtering. Pure Ti target was sputtered under a mixture of argon and oxygen plasma, in which the argon to oxygen flow rate ratio is 1:4. Finally, TiO2 coated PDMS structures were treated by O2 plasma at a low plasma power of 6.8 Watt with different treatment times. The micro crack of TiO2 thin film observed by optical microscope was found to be uniformly distributed on the PDMS surface. The crystal structure of TiO2 investigated by X-ray diffraction (XRD) confirms that the structure TiO2 thin film on PDMS is amorphous. To characterize the hydrophilic property, the contact angle of PDMS and TiO2 coated PDMS were measured as a function of oxygen plasma treatment time. It was found that the contact angle of treated PDMS is dropped from 117 to 9 degrees after oxygen plasma treatment for 1 minute. While the contact angle of TiO2 coated PDMS is sharply dropped from 88 to 7.8 degrees after oxygen plasma treatment for 1 minute. Therefore, the improvement of hydrophilicity surface properties of PDMS is successfully obtained by TiO2 thin film coating and subsequent oxygen plasma treatment.","PeriodicalId":6415,"journal":{"name":"2007 7th IEEE Conference on Nanotechnology (IEEE NANO)","volume":"26 1","pages":"911-913"},"PeriodicalIF":0.0000,"publicationDate":"2007-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th IEEE Conference on Nanotechnology (IEEE NANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NANO.2007.4601331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

We present the modification of polydimethylsiloxane (PDMS) surface by titanium dioxide (TiO2) thin film coating and subsequent oxygen plasma treatment. TiO2 thin film was deposited on the prepared PDMS samples by reactive dc sputtering. Pure Ti target was sputtered under a mixture of argon and oxygen plasma, in which the argon to oxygen flow rate ratio is 1:4. Finally, TiO2 coated PDMS structures were treated by O2 plasma at a low plasma power of 6.8 Watt with different treatment times. The micro crack of TiO2 thin film observed by optical microscope was found to be uniformly distributed on the PDMS surface. The crystal structure of TiO2 investigated by X-ray diffraction (XRD) confirms that the structure TiO2 thin film on PDMS is amorphous. To characterize the hydrophilic property, the contact angle of PDMS and TiO2 coated PDMS were measured as a function of oxygen plasma treatment time. It was found that the contact angle of treated PDMS is dropped from 117 to 9 degrees after oxygen plasma treatment for 1 minute. While the contact angle of TiO2 coated PDMS is sharply dropped from 88 to 7.8 degrees after oxygen plasma treatment for 1 minute. Therefore, the improvement of hydrophilicity surface properties of PDMS is successfully obtained by TiO2 thin film coating and subsequent oxygen plasma treatment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
溅射TiO2薄膜在PDMS表面改性中的氧等离子体处理
采用二氧化钛(TiO2)薄膜涂层和氧等离子体处理对聚二甲基硅氧烷(PDMS)表面进行改性。通过反应直流溅射在制备的PDMS样品上沉积TiO2薄膜。在氩氧比为1:4的混合氩氧等离子体中溅射纯钛靶。最后,采用低等离子体功率(6.8 w)不同处理次数的O2等离子体处理TiO2包覆PDMS结构。光学显微镜观察到TiO2薄膜的微裂纹均匀分布在PDMS表面。通过x射线衍射(XRD)对TiO2的晶体结构进行了研究,证实了TiO2薄膜在PDMS上的结构是无定形的。为了表征PDMS和TiO2涂层PDMS的亲水性,我们测量了接触角与氧等离子体处理时间的关系。经氧等离子体处理1分钟后,处理后的PDMS接触角由117度下降到9度。而经氧等离子体处理1分钟后,TiO2涂层PDMS的接触角从88度急剧下降到7.8度。因此,通过TiO2薄膜涂层和随后的氧等离子体处理,成功地改善了PDMS的亲水性表面性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Schrödinger Equation Monte Carlo-3D for simulation of nanoscale MOSFETs Young's Modulus of High Aspect Ratio Si3N4 Nano-thickness Membrane Quantum well nanomechanical actuators with atomic vertical resolution Study of nanopattern forming with chemical coatings for silicon-based stamp in nanoimprint process Surface energy induced patterning of polymer nanostructures for cancer diagnosis and therapy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1