Hospital-based Dose Survey, an Impetus to a National Diagnostic Reference Level in Chest X-Ray Examinations

V. A. G. Torio, A. Peralta
{"title":"Hospital-based Dose Survey, an Impetus to a National Diagnostic Reference Level in Chest X-Ray Examinations","authors":"V. A. G. Torio, A. Peralta","doi":"10.7718/IAMURE.IJHE.V5I1.847","DOIUrl":null,"url":null,"abstract":"Diagnostic Reference Levels (DRLs) are significant in diagnostic radiology. Currently, there is no established diagnostic reference level in any radiographic procedure in the Philippines. The study aimed to determine doses received by patients undergoing chest posteroanterior (PA) x-ray examinations. In addition, the study also aimed to provide an estimate of entrance surface dose for chest PA for later basis in establishing DRLs in the country. It used a dose survey to collect data. Instruments were used to measure the dose received by the subjects of the study. The result of the data gathering revealed a dose estimate of 0.15± 0.06 mGy which is lower than the reference/guidance levels set by two international organizations: (1) the European Commission (EC, 1997) and (2) the International Atomic Energy Agency (IAEA, 2007).  It is also relatively lower than the doses measured in similar studies in other countries. The result of the study gives an indication of good radiography practice in the tertiary hospital where the study was conducted. It is recommended that the data in this study together with data from other studies for the same procedure conducted in the country be used in establishing a DRL for chest radiography in the Philippines. Keywords - Radiology, diagnostic Reference Levels (DRL), Entrance Surface Dose (ESD),descriptive method, Philippines","PeriodicalId":75938,"journal":{"name":"International journal of health education","volume":"43 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2014-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of health education","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7718/IAMURE.IJHE.V5I1.847","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Diagnostic Reference Levels (DRLs) are significant in diagnostic radiology. Currently, there is no established diagnostic reference level in any radiographic procedure in the Philippines. The study aimed to determine doses received by patients undergoing chest posteroanterior (PA) x-ray examinations. In addition, the study also aimed to provide an estimate of entrance surface dose for chest PA for later basis in establishing DRLs in the country. It used a dose survey to collect data. Instruments were used to measure the dose received by the subjects of the study. The result of the data gathering revealed a dose estimate of 0.15± 0.06 mGy which is lower than the reference/guidance levels set by two international organizations: (1) the European Commission (EC, 1997) and (2) the International Atomic Energy Agency (IAEA, 2007).  It is also relatively lower than the doses measured in similar studies in other countries. The result of the study gives an indication of good radiography practice in the tertiary hospital where the study was conducted. It is recommended that the data in this study together with data from other studies for the same procedure conducted in the country be used in establishing a DRL for chest radiography in the Philippines. Keywords - Radiology, diagnostic Reference Levels (DRL), Entrance Surface Dose (ESD),descriptive method, Philippines
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于医院的剂量调查,推动胸透检查的国家诊断参考水平
诊断参考水平(drl)在诊断放射学中具有重要意义。目前,在菲律宾的任何放射检查程序中都没有确定的诊断参考水平。该研究旨在确定接受胸部后前(PA) x光检查的患者所接受的剂量。此外,该研究还旨在为今后在该国建立DRLs提供胸部PA的入口表面剂量估计。它使用剂量调查来收集数据。研究人员使用仪器测量研究对象接受的剂量。数据收集的结果显示,剂量估计为0.15±0.06毫格瑞,低于两个国际组织设定的参考/指导水平:(1)欧洲委员会(欧委会,1997年)和(2)国际原子能机构(原子能机构,2007年)。这也比在其他国家进行的类似研究中测量到的剂量要低。该研究的结果给出了良好的放射实践在三级医院进行研究的指示。建议将本研究的数据与在该国进行的其他相同程序研究的数据一起用于建立菲律宾胸部x线摄影的DRL。关键词:放射学,诊断参考水平(DRL),入口表面剂量(ESD),描述方法,菲律宾
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Knowledge of medical students about perioperative nutritional care in Bahia, Brazil: a transversal study A relação entre a vida acadêmica e a vida familiar do estudante de medicina: uma análise transversal Potentialities and weaknesses of Education and Interprofessional Work in health: perspectives of professionals in Northeast Brazil Evaluation of the simulation design scale in medical students Pedagogical impact of internal training applied to the Academic League of Internal and Surgical Medicine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1