Detection tests of imaging devices based on silicon pixel-array detectors assembled using Tape Automated Bonding and microcable technologies

V. Borshchov, D. Burdette, E. Chesi, V. Cindro, N. Clinthorne, E. Cochran, B. Grošičar, K. Honscheid, H. Kagan, C. Lacasta, O. Listratenko, G. Llosá, M. Mikuž, M. Protsenko, V. Stankova, A. Studen, I. Tymchuk, P. Weilhammer, D. Žontar, V. Linhart
{"title":"Detection tests of imaging devices based on silicon pixel-array detectors assembled using Tape Automated Bonding and microcable technologies","authors":"V. Borshchov, D. Burdette, E. Chesi, V. Cindro, N. Clinthorne, E. Cochran, B. Grošičar, K. Honscheid, H. Kagan, C. Lacasta, O. Listratenko, G. Llosá, M. Mikuž, M. Protsenko, V. Stankova, A. Studen, I. Tymchuk, P. Weilhammer, D. Žontar, V. Linhart","doi":"10.1109/NSSMIC.2010.5874393","DOIUrl":null,"url":null,"abstract":"Detection and spectroscopic tests of three self-triggered silicon detection modules constructed using Tape Automated Bonding and micro-cable technologies and equipped by VATA read-out chips are presented and compared. Results of these tests are demonstrated using hit maps and pulse-height spectra induced by 133Ba, 241Am, and 57Co radioactive sources of X- and gamma rays. We have observed significant improvement in measurement of hit maps in the cases of first and second detector modules. The hit maps of the first detector module have proven that some problems occur in addressing certain VATA chip channels. Whereas, the hit maps of the second detector module is correct. On the other side, spectroscopic resolution given by the Full Width at Half Maximum (FWHM) of the first detection module is below 2 keV which is compatible with measurements on wire bonded modules. The FWHM of the second module is approximately two times worse.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"6 1","pages":"3194-3196"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Detection and spectroscopic tests of three self-triggered silicon detection modules constructed using Tape Automated Bonding and micro-cable technologies and equipped by VATA read-out chips are presented and compared. Results of these tests are demonstrated using hit maps and pulse-height spectra induced by 133Ba, 241Am, and 57Co radioactive sources of X- and gamma rays. We have observed significant improvement in measurement of hit maps in the cases of first and second detector modules. The hit maps of the first detector module have proven that some problems occur in addressing certain VATA chip channels. Whereas, the hit maps of the second detector module is correct. On the other side, spectroscopic resolution given by the Full Width at Half Maximum (FWHM) of the first detection module is below 2 keV which is compatible with measurements on wire bonded modules. The FWHM of the second module is approximately two times worse.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于硅像素阵列探测器的成像设备检测测试,采用胶带自动粘合和微电缆技术组装
介绍并比较了三种采用胶带自动粘接和微电缆技术构建的、配备VATA读出芯片的自触发硅检测模块的检测和光谱测试。这些测试的结果用X射线和伽马射线的133Ba、241Am和57Co放射源诱导的命中图和脉冲高度谱来证明。我们观察到,在第一和第二检测器模块的情况下,命中图的测量有了显著的改进。第一个检测器模块的命中图已经证明在寻址某些VATA芯片通道时会出现一些问题。而第二个探测器模块的命中图是正确的。另一方面,第一个检测模块的半最大全宽(FWHM)给出的光谱分辨率低于2 keV,这与线键合模块的测量兼容。第二个模块的FWHM大约差两倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
CaF2(Eu): An “Old” scintillator revisited Evaluation of the accuracy and robustness of a motion correction algorithm for PET using a novel phantom approach The performance of GridPix detectors Applying the neutron scatter camera to treaty verification and warhead monitoring Development of an 8-channel time based readout ASIC for PET applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1