Modeling and Analysis of STATCOM for Renewable Energy Farm to Improve Power Quality and Reactive Power Compensation

M. Tariq, H. Zaheer, T. Mahmood
{"title":"Modeling and Analysis of STATCOM for Renewable Energy Farm to Improve Power Quality and Reactive Power Compensation","authors":"M. Tariq, H. Zaheer, T. Mahmood","doi":"10.3390/engproc2021012044","DOIUrl":null,"url":null,"abstract":"Power Quality (PQ) improvement in grid-integrated photovoltaic (PV) and wind energy hybrid systems for effective power transfer is presented in this paper. Due to interlinked hybrid renewable energy resources and nonlinear loads, various issues arise which affect the power quality, i.e., voltage sag, harmonic distortion increases, and also reactive power demand. In order to mitigate these issues, flexible alternating current transmission system (FACTS) devices are utilized. In this paper, hysteresis band current controller (HBCC)-based static synchronous compensator (STATCOM) is modeled to reduce PQ problems. HBCC is a robust and simple technique to improve voltage profile, reduce total harmonic distortion (THD) and fulfill the reactive power demand. Two case scenarios of the hybrid system, i.e., (I) grid integrated hybrid system without HBCC (II) grid integrated hybrid system with HBCC, are tested. Results demonstrate that under scenario II, load bus voltage is regulated at 1.0 p.u., THD of system voltage and current is reduced 0.25% and 0.35%, respectively, and reactive power demand of 30 kVAR is fulfilled. The HBCC was designed for reducing THD of the system with the limits specified by standards IEEE 519-1992 STATCOM using hysteresis band current controller to improve power quality in the distribution system which is simulated using MATLAB/SIMULINK. After that, the performance of the system is better in terms of power quality.","PeriodicalId":11748,"journal":{"name":"Engineering Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/engproc2021012044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Power Quality (PQ) improvement in grid-integrated photovoltaic (PV) and wind energy hybrid systems for effective power transfer is presented in this paper. Due to interlinked hybrid renewable energy resources and nonlinear loads, various issues arise which affect the power quality, i.e., voltage sag, harmonic distortion increases, and also reactive power demand. In order to mitigate these issues, flexible alternating current transmission system (FACTS) devices are utilized. In this paper, hysteresis band current controller (HBCC)-based static synchronous compensator (STATCOM) is modeled to reduce PQ problems. HBCC is a robust and simple technique to improve voltage profile, reduce total harmonic distortion (THD) and fulfill the reactive power demand. Two case scenarios of the hybrid system, i.e., (I) grid integrated hybrid system without HBCC (II) grid integrated hybrid system with HBCC, are tested. Results demonstrate that under scenario II, load bus voltage is regulated at 1.0 p.u., THD of system voltage and current is reduced 0.25% and 0.35%, respectively, and reactive power demand of 30 kVAR is fulfilled. The HBCC was designed for reducing THD of the system with the limits specified by standards IEEE 519-1992 STATCOM using hysteresis band current controller to improve power quality in the distribution system which is simulated using MATLAB/SIMULINK. After that, the performance of the system is better in terms of power quality.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于STATCOM的可再生能源电厂电能质量改善与无功补偿建模与分析
提出了提高光伏和风能并网混合系统电能质量以实现有效电能传输的方法。由于混合可再生能源资源的互联性和非线性负荷的存在,产生了各种影响电能质量的问题,如电压暂降、谐波失真增加以及无功需求。为了缓解这些问题,柔性交流传输系统(FACTS)设备被使用。本文建立了基于磁滞带电流控制器(HBCC)的静态同步补偿器(STATCOM)模型,以减少PQ问题。HBCC是一种简单、可靠的改善电压分布、降低总谐波失真(THD)和满足无功需求的技术。对混合动力系统的两种情况进行了测试,即(I)不含HBCC的电网综合混合动力系统(II)带HBCC的电网综合混合动力系统。结果表明,在方案II下,将负载母线电压调节在1.0 p.u,系统电压和电流的THD分别降低0.25%和0.35%,满足30 kVAR的无功需求。采用滞回带电流控制器,在符合IEEE 519-1992 STATCOM标准的条件下降低系统的THD,改善配电系统的电能质量,并利用MATLAB/SIMULINK进行了仿真。在此之后,系统在电能质量方面的性能更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
0
期刊最新文献
MNET: Semantic Segmentation for Satellite Images Based on Multi-Channel Decomposition Location-Assistive and Real-Time Query IoT-Based Transport System The Thermal Analysis of a Sensible Heat Thermal Energy Storage System Using Circular-Shaped Slag and Concrete for Medium- to High-Temperature Applications Performance Enhancement of Photovoltaic Water Pumping System Based on BLDC Motor under Partial Shading Condition Solar Powered DC Refrigerator for Small Scale Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1