{"title":"All Fiber Temperature Sensor Based on TMD Alloy Coated Tapered Fiber","authors":"S. Tan, Z. C. Tiu, X. S. Cheng, H. Ahmad","doi":"10.1109/ICP46580.2020.9206484","DOIUrl":null,"url":null,"abstract":"All fiber temperature sensor based on $\\mathrm{MoWS}_{2}- \\mathrm{rGO}$ coated tapered fiber is demonstrated. The large evanescent field of tapered fiber allows $\\mathrm{MoWS}_{2}-\\mathrm{rGO}$ coated tapered fiber to absorb the surrounding heat and changes the refractive index of $\\mathrm{MoWS}_{2}-\\mathrm{rGO}$ coated tapered fiber. The refractive index change is due to thermo-optic effect. When there is a change of surrounding temperature, the refractive index of the coated tapered fiber changes and this subsequently alters the incident light polarization. The sensitivity of the proposed temperature sensor is measured at 0.63°/°C. This is the first demonstration of using $\\mathrm{MoWS}_{2}-\\mathrm{rGO}$ tapered fiber as temperature sensor.","PeriodicalId":6758,"journal":{"name":"2020 IEEE 8th International Conference on Photonics (ICP)","volume":"51 1","pages":"89-90"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 8th International Conference on Photonics (ICP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICP46580.2020.9206484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

All fiber temperature sensor based on $\mathrm{MoWS}_{2}- \mathrm{rGO}$ coated tapered fiber is demonstrated. The large evanescent field of tapered fiber allows $\mathrm{MoWS}_{2}-\mathrm{rGO}$ coated tapered fiber to absorb the surrounding heat and changes the refractive index of $\mathrm{MoWS}_{2}-\mathrm{rGO}$ coated tapered fiber. The refractive index change is due to thermo-optic effect. When there is a change of surrounding temperature, the refractive index of the coated tapered fiber changes and this subsequently alters the incident light polarization. The sensitivity of the proposed temperature sensor is measured at 0.63°/°C. This is the first demonstration of using $\mathrm{MoWS}_{2}-\mathrm{rGO}$ tapered fiber as temperature sensor.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于TMD合金涂层锥形光纤的全光纤温度传感器
介绍了基于$\ mathm {MoWS}_{2}- $ mathm {rGO}$涂层锥形光纤的全光纤温度传感器。锥形光纤的大倏逝场使得$\ mathm {MoWS}_{2}-\ mathm {rGO}$涂层锥形光纤能够吸收周围的热量,从而改变$\ mathm {MoWS}_{2}-\ mathm {rGO}$涂层锥形光纤的折射率。折射率的变化是由于热光学效应。当周围温度发生变化时,涂层锥形光纤的折射率发生变化,从而改变入射光的偏振。所提出的温度传感器的灵敏度在0.63°/°C测量。这是使用$\ mathm {MoWS}_{2}- $ mathm {rGO}$锥形光纤作为温度传感器的首次演示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Temperature Sensor based on 1D SiN/Air Photonic Crystal Research on reconstruction algorithm of lensless microimaging High spatial resolution microscopy with functional thin film Fiber Sensor for Simultaneous Measurement of Heart and Breath Rate on SmartBed Photoluminescence and Raman Studies on $\mathrm{GaAs}_{1-\mathrm{x}}\mathrm{Bi}_{\mathrm{X}}$ Grown on GaAs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1