Reliability study of AlTi/TiW, polysilicon and ohmic contacts for piezoresistive pressure sensors applications

A. Andrei, C. Malhaire, S. Brida, D. Barbier
{"title":"Reliability study of AlTi/TiW, polysilicon and ohmic contacts for piezoresistive pressure sensors applications","authors":"A. Andrei, C. Malhaire, S. Brida, D. Barbier","doi":"10.1109/ICSENS.2004.1426374","DOIUrl":null,"url":null,"abstract":"This paper presents a study on the thermal drift and long term stability of AlTi (with a TiW diffusion barrier) metal lines, polysilicon gauges and metal on polysilicon contact resistances for piezoresistive pressure sensors operating in harsh environments. Test structures have been exposed at 150/spl deg/C for a cumulated time of almost six months. All metal lines structures show a relative resistance decrease of around 4/spl times/10/sup -3/. On the other hand, polysilicon resistivity variations were not observable except for a few samples that showed a relative increase up to 7/spl times/10/sup -3/. Polysilicon contact resistance showed no particular trend with aging time. The impact of these results on the overall sensor reliability has also been discussed.","PeriodicalId":20476,"journal":{"name":"Proceedings of IEEE Sensors, 2004.","volume":"57 1","pages":"1125-1128 vol.3"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Sensors, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2004.1426374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper presents a study on the thermal drift and long term stability of AlTi (with a TiW diffusion barrier) metal lines, polysilicon gauges and metal on polysilicon contact resistances for piezoresistive pressure sensors operating in harsh environments. Test structures have been exposed at 150/spl deg/C for a cumulated time of almost six months. All metal lines structures show a relative resistance decrease of around 4/spl times/10/sup -3/. On the other hand, polysilicon resistivity variations were not observable except for a few samples that showed a relative increase up to 7/spl times/10/sup -3/. Polysilicon contact resistance showed no particular trend with aging time. The impact of these results on the overall sensor reliability has also been discussed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
压阻式压力传感器中AlTi/TiW、多晶硅和欧姆触点的可靠性研究
本文研究了在恶劣环境下工作的压阻式压力传感器的AlTi(带有TiW扩散阻挡层)金属线、多晶硅表和金属对多晶硅接触电阻的热漂移和长期稳定性。测试结构已暴露在150/spl度/C下累计时间近6个月。所有金属线结构的相对电阻都降低了约4/spl倍/10/sup -3/。另一方面,除了少数样品显示相对增加了7/spl倍/10/sup -3/外,没有观察到多晶硅电阻率变化。多晶硅接触电阻随老化时间无明显变化趋势。这些结果对传感器整体可靠性的影响也进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of non-invasive optical transcutaneous pCO/sub 2/ gas sensor and analytic equipment Implantable flexible wireless pressure sensor module Surface quad beam polymer optical accelerometer Fabrication and initial characterisation results of a micromachined biomimetic strain sensor inspired from the Campaniform sensillum of insects Wireless multi-channel sensor for neurodynamic studies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1