{"title":"DC SQUID-based position detector for gravitational experiments","authors":"W. Vodel,&nbsp;S. Nietzsche,&nbsp;H. Koch,&nbsp;Glyscinski J.v. Zameck","doi":"10.1016/S0964-1807(99)00040-X","DOIUrl":null,"url":null,"abstract":"<div><p>Experiments like the test of the weak equivalence principle at the Bremen drop-tower, Germany, and STEP (Satellite Test of the Equivalence Principle) require a position detector with an extremely high resolution to measure tiny displacements of free falling test bodies.</p><p>In order to develop a SQUID position detector numerous configurations of test bodies and pick-up coils with different geometries were tested experimentally. As a function of the position of the test body the inductance of the pick-up coil was measured with a commercial LCR meter as well as with a LTS DC SQUID system. This SQUID system, which is developed and manufactured at the Jena University, provides high sensitivity and extremely low intrinsic noise, especially at low frequencies.</p><p>This contribution will also discuss some recent results in measuring the motion of one body during its free fall over 109<!--> <!-->m at the Bremen drop-tower.</p></div>","PeriodicalId":100110,"journal":{"name":"Applied Superconductivity","volume":"6 10","pages":"Pages 767-775"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0964-1807(99)00040-X","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Superconductivity","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S096418079900040X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Experiments like the test of the weak equivalence principle at the Bremen drop-tower, Germany, and STEP (Satellite Test of the Equivalence Principle) require a position detector with an extremely high resolution to measure tiny displacements of free falling test bodies.

In order to develop a SQUID position detector numerous configurations of test bodies and pick-up coils with different geometries were tested experimentally. As a function of the position of the test body the inductance of the pick-up coil was measured with a commercial LCR meter as well as with a LTS DC SQUID system. This SQUID system, which is developed and manufactured at the Jena University, provides high sensitivity and extremely low intrinsic noise, especially at low frequencies.

This contribution will also discuss some recent results in measuring the motion of one body during its free fall over 109 m at the Bremen drop-tower.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于直流squid的重力实验位置探测器
德国不来梅落塔的弱等效原理测试和STEP(等效原理卫星测试)等实验需要具有极高分辨率的位置探测器来测量自由落体的微小位移。为了研制SQUID位置探测器,对不同几何形状的测试体和拾取线圈进行了实验测试。作为测试体位置的函数,用商用LCR仪表和LTS直流SQUID系统测量了拾取线圈的电感。这种SQUID系统由耶拿大学开发和制造,具有高灵敏度和极低的固有噪声,特别是在低频时。本文还将讨论在不来梅落体塔自由落体超过109米时测量物体运动的一些最新结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Raw data and analysis pipeline for producing figures in F.W. Carter, et. al., 2016 Review and evaluation of methods for application of epitaxial buffer and superconductor layers1 10 K NbN ADC for IR sensor applications Optically-induced effects in Y–ba–cu–O Josephson junctions Cell-library design methodology for integrated RSFQ-logic
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1