Study of polarization evolution in phantom tissues with ultrafast optics techniques: Monte Carlo simulations and experiments

Xueding Wang, L.V. Wang, Chia-Wei Sun, Hsiang-Shi Wang, C.C. Yang, Y. Kiang
{"title":"Study of polarization evolution in phantom tissues with ultrafast optics techniques: Monte Carlo simulations and experiments","authors":"Xueding Wang, L.V. Wang, Chia-Wei Sun, Hsiang-Shi Wang, C.C. Yang, Y. Kiang","doi":"10.1109/IEMBS.2002.1053303","DOIUrl":null,"url":null,"abstract":"This paper presents our study results of polarized short pulse transmission through phantom tissues made of polystyrene particle solutions with various concentrations and particle sizes. To improve the quality of optical imaging using an ultrafast light source, study is required to fully understand the evolution of the polarization state in the sample, as well as the time- and polarization-dependent distributions of optical intensity exiting from samples. Temporal profiles of the Stokes vectors and the degree of polarization are measured experimentally. The results agree well with those resulting from Monte Carlo simulations. Analyses based on the Stokes-Mueller formalism show that the first scattering event determines the spatial patterns of the transmitted Stokes vectors. When a detected area at the output surface of the sample is symmetric about the incident beam, the temporal profile of transmittance is independent of the incident polarization state. The linear relationship between the average order of scatters and the light propagation time can be used to explain the exponential decay of the degree of polarization and the inversely proportional relationship between the FWHM of the degree of polarization and the scatterer concentration.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":"16 1","pages":"2323-2324 vol.3"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1053303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents our study results of polarized short pulse transmission through phantom tissues made of polystyrene particle solutions with various concentrations and particle sizes. To improve the quality of optical imaging using an ultrafast light source, study is required to fully understand the evolution of the polarization state in the sample, as well as the time- and polarization-dependent distributions of optical intensity exiting from samples. Temporal profiles of the Stokes vectors and the degree of polarization are measured experimentally. The results agree well with those resulting from Monte Carlo simulations. Analyses based on the Stokes-Mueller formalism show that the first scattering event determines the spatial patterns of the transmitted Stokes vectors. When a detected area at the output surface of the sample is symmetric about the incident beam, the temporal profile of transmittance is independent of the incident polarization state. The linear relationship between the average order of scatters and the light propagation time can be used to explain the exponential decay of the degree of polarization and the inversely proportional relationship between the FWHM of the degree of polarization and the scatterer concentration.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用超快光学技术研究幻影组织的偏振演化:蒙特卡罗模拟与实验
本文介绍了偏振短脉冲通过不同浓度和粒径的聚苯乙烯粒子溶液制备的幻像组织的研究结果。为了提高使用超快光源的光学成像质量,需要研究充分了解样品中偏振状态的演变,以及样品中光强随时间和偏振的分布。实验测量了Stokes矢量的时域分布和偏振度。结果与蒙特卡罗模拟结果吻合较好。基于Stokes- mueller形式的分析表明,第一次散射事件决定了传输Stokes矢量的空间模式。当样品输出表面的检测区域与入射光束对称时,透射率的时间分布与入射偏振态无关。散射体平均阶数和光传播时间的线性关系可以用来解释偏振度的指数衰减和偏振度的频宽与散射体浓度的反比关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
368
期刊最新文献
Contour extraction of fetus' head from echocardiogram using Snakes Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems Left ventricular volume changes after defibrillation Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT Comparative in vivo and ex vivo pacing and sensing performance study using isolated four-chamber working swine heart model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1