Zhihua Liu, C. Cai, Mei Yu, Yanxiang Xia, Jingsheng Li
{"title":"Analysis on the Resonance Frequency of Comparison Calibration of the Piezoelectric Accelerometer","authors":"Zhihua Liu, C. Cai, Mei Yu, Yanxiang Xia, Jingsheng Li","doi":"10.1109/ICISCE.2016.188","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is to present an analysis on the resonance frequency of comparison calibration of the piezoelectric accelerometer to guarantee the accuracy and reliability of the calibration results. The operation principle of the piezoelectric accelerometer is firstly introduced and the natural frequency is obtained. Then, the vibration model of the comparison calibration is established and the mounted resonance frequency of the calibrated sensitivity is derived. The entire resonance frequency is achieved which is based on the deduced general form of the relative motion of the comparison calibration. The mounted resonance frequency is close to the entire resonance frequency at low mounted stiffness and approaches to the natural frequency as the mounted stiffness increases. The experimental results demonstrate that the mounted resonance frequency increases with the mounted stiffness. For the sake of high frequency calibration, the mounted stiffness should be kept high enough and the stude with silicone grease mounted method is a good choice.","PeriodicalId":6882,"journal":{"name":"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISCE.2016.188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The purpose of this paper is to present an analysis on the resonance frequency of comparison calibration of the piezoelectric accelerometer to guarantee the accuracy and reliability of the calibration results. The operation principle of the piezoelectric accelerometer is firstly introduced and the natural frequency is obtained. Then, the vibration model of the comparison calibration is established and the mounted resonance frequency of the calibrated sensitivity is derived. The entire resonance frequency is achieved which is based on the deduced general form of the relative motion of the comparison calibration. The mounted resonance frequency is close to the entire resonance frequency at low mounted stiffness and approaches to the natural frequency as the mounted stiffness increases. The experimental results demonstrate that the mounted resonance frequency increases with the mounted stiffness. For the sake of high frequency calibration, the mounted stiffness should be kept high enough and the stude with silicone grease mounted method is a good choice.