{"title":"Portable double-focusing mass-spectrometer system for field gas monitoring","authors":"Jorge A. Diaz, Clayton F. Giese, W. Ronald Gentry","doi":"10.1002/fact.1016","DOIUrl":null,"url":null,"abstract":"<p>Traditional mass-spectrometry (MS) instruments have been confined to laboratory usage because of their large size, power and high-vacuum requirements, which make them unsuitable for use in most field environments. Developments in mass spectrometers and small vacuum pump systems have now made possible the development of transportable mass-spectrometer instruments. A portable MS device based on a miniature double-focusing <i>(ExB)</i> sector-field mass spectrometer has been developed for in situ gas analysis and monitoring applications. The device (acronym Portable-CDFMS) uses a 1.1-Tesla NdFeB permanent magnet, a lithographically defined electric sector, a molecular-flow frit inlet, a spiral filament in a closed ion source, and a miniature channeltron detector. The high vacuum is provided with the use of a very compact hybrid turbomolecular and diaphragm pump combination. This MS system weighs 18 lb., is able to detect atmospheric species at the part-per-million (ppm) level, and has a mass range up to 200 amu, which makes this miniature mass spectrometer well suited for field applications. © 2001 John Wiley & Sons, Inc. Field Analyt Chem Technol 5: 156–167, 2001</p>","PeriodicalId":100527,"journal":{"name":"Field Analytical Chemistry & Technology","volume":"5 3","pages":"156-167"},"PeriodicalIF":0.0000,"publicationDate":"2001-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/fact.1016","citationCount":"27","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry & Technology","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/fact.1016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27
Abstract
Traditional mass-spectrometry (MS) instruments have been confined to laboratory usage because of their large size, power and high-vacuum requirements, which make them unsuitable for use in most field environments. Developments in mass spectrometers and small vacuum pump systems have now made possible the development of transportable mass-spectrometer instruments. A portable MS device based on a miniature double-focusing (ExB) sector-field mass spectrometer has been developed for in situ gas analysis and monitoring applications. The device (acronym Portable-CDFMS) uses a 1.1-Tesla NdFeB permanent magnet, a lithographically defined electric sector, a molecular-flow frit inlet, a spiral filament in a closed ion source, and a miniature channeltron detector. The high vacuum is provided with the use of a very compact hybrid turbomolecular and diaphragm pump combination. This MS system weighs 18 lb., is able to detect atmospheric species at the part-per-million (ppm) level, and has a mass range up to 200 amu, which makes this miniature mass spectrometer well suited for field applications. © 2001 John Wiley & Sons, Inc. Field Analyt Chem Technol 5: 156–167, 2001
用于野外气体监测的便携式双聚焦质谱仪系统
传统的质谱(MS)仪器由于体积大,功率大,要求高真空,因此不适合在大多数现场环境中使用,因此仅限于实验室使用。质谱仪和小型真空泵系统的发展使可运输质谱仪的研制成为可能。研制了一种基于微型双聚焦扇形场质谱仪的便携式质谱仪,用于现场气体分析和监测。该装置(首字母缩写为Portable-CDFMS)使用1.1特斯拉钕铁硼永磁体、光刻定义的电扇区、分子流熔块入口、封闭离子源中的螺旋灯丝和微型通道电子探测器。使用非常紧凑的混合涡轮分子和隔膜泵组合提供高真空。该质谱系统重18磅,能够检测百万分之一(ppm)水平的大气物质,质量范围可达200 amu,这使得该微型质谱仪非常适合现场应用。©2001 John Wiley &儿子,Inc。化学工程学报(英文版),2001
本文章由计算机程序翻译,如有差异,请以英文原文为准。