Minicolumn field sampling and flow-injection-atomic absorption spectrometric determination of lead in seawater

M. C. Yebra, N. Carro, A. Moreno-Cid, L. Puig
{"title":"Minicolumn field sampling and flow-injection-atomic absorption spectrometric determination of lead in seawater","authors":"M. C. Yebra,&nbsp;N. Carro,&nbsp;A. Moreno-Cid,&nbsp;L. Puig","doi":"10.1002/fact.10003","DOIUrl":null,"url":null,"abstract":"<p>A simple field-flow preconcentration system has been developed for lead determination in seawater. Seawater samples are collected in situ by passing them with a pump through minicolumns packed with poly(aminophosphonic acid) chelating resin to retain and preconcentrate lead, and remove the saline matrix. Minicolumns loaded with lead are then returned to the laboratory where they are inserted into a flow-injection system and eluted with a small volume of hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. The detection limit for lead in seawater was 2.8 ng l<sup>−1</sup>. This procedure was applied to the determination of lead in seawater samples from Galicia (Spain). © 2001 John Wiley &amp; Sons, Inc. Field Analyt Chem Technol 5: 239–243, 2001</p>","PeriodicalId":100527,"journal":{"name":"Field Analytical Chemistry & Technology","volume":"5 5","pages":"239-243"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/fact.10003","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry & Technology","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/fact.10003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

A simple field-flow preconcentration system has been developed for lead determination in seawater. Seawater samples are collected in situ by passing them with a pump through minicolumns packed with poly(aminophosphonic acid) chelating resin to retain and preconcentrate lead, and remove the saline matrix. Minicolumns loaded with lead are then returned to the laboratory where they are inserted into a flow-injection system and eluted with a small volume of hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. The detection limit for lead in seawater was 2.8 ng l−1. This procedure was applied to the determination of lead in seawater samples from Galicia (Spain). © 2001 John Wiley & Sons, Inc. Field Analyt Chem Technol 5: 239–243, 2001

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小柱现场取样-流动注射-原子吸收光谱法测定海水中铅
研制了一种简单的场流富集法测定海水中的铅。海水样品是通过泵通过填充有聚氨基膦酸螯合树脂的小型柱来就地收集的,以保留和预浓缩铅,并去除盐水基质。然后,装载铅的微型柱被送回实验室,在那里它们被插入流动注射系统,并用少量盐酸洗脱,进入火焰原子吸收光谱仪的雾化器燃烧器系统。海水中铅的检出限为2.8 ng l−1。本方法应用于西班牙加利西亚海水样品中铅的测定。©2001 John Wiley &儿子,Inc。化学工程学报,2009,29 (5):379 - 379
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Technological innovation in field analytical chemistry A compact optical system for multi-determination of biochemical oxygen demand using disposable strips On-site gas chromatographic determination of explosives in soils Real-time classification performance and failure mode analysis of a physical/chemical sensor array and a probabilistic neural network Minicolumn field sampling and flow-injection-atomic absorption spectrometric determination of lead in seawater
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1