Aquifer characteristics and groundwater flow system in a typical basement complex and Gundumi formation northwest, Nigeria

A. Shuaibu, M. Garba, I. Abubakar
{"title":"Aquifer characteristics and groundwater flow system in a typical basement complex and Gundumi formation northwest, Nigeria","authors":"A. Shuaibu, M. Garba, I. Abubakar","doi":"10.4314/bajopas.v15i1.4","DOIUrl":null,"url":null,"abstract":"Aquifer performance was tested in 280 locations of the study area to assess the hydraulic characteristics of the various aquifers, potential yield from the flowing boreholes of both hard rocks and sedimentary formation underlain Zamfara State Northwestern, Nigeria. Pumping test result were subjected to standard methods of Jacob’s and modified Theis equation for evaluation of aquifer parameters such as hydraulic conductivity (K), Transmissivity (T), Specific capacity and others. The results show that characteristic of areas underlain by crystalline rock units, especially migmatite, variably migmatized gneiss, schists and granites are characterized by thin/shallow overburden unit of usually less than 10m. In such settings the borehole depth varies from 38 to 78m while saturated thickness varies from 8 to 20m below ground level, with average yield of 44.1m3/day. Hydrogeological parameters obtained from pumping test analysis within the basement rock units revealed aquifer transmissivity (T) values which range from 0.14 to 141.23m2/day, with an average of 12.85m2/day. This implies aquifers of negligible to high potentials. The hydraulic conductivity (K) values vary from 5.0 x 10-2m/day and 8.8 x 10-1m/day with an average of 2.2 x 10-1m/day. The implication of these results is that the aquifers of the basement rock units cannot provide sufficient water for both domestic and agricultural needs of the area. However, Sixty-eight (68) analyzed borehole data set within Gundumi Formation, revealed the average discharge rate of 116.8m3/day. This formation shows the highest water discharge within the study area. The average penetration depth of 65m was achieved. The hydraulic conductivity of this aquifer revealed average value of 5.7 × 10-1m/day. This implies high permeability of aquifer system, which is typical of sedimentary formation of this nature. Transmissivity (T) revealed an average value of 38.89m2/day, which indicate high rate of water flow through the entire aquifer medium of this formation. The geospatial analysis of yield from the wells indicate excellent groundwater potential around the western part of the study area.","PeriodicalId":8734,"journal":{"name":"Bayero Journal of Pure and Applied Sciences","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bayero Journal of Pure and Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/bajopas.v15i1.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aquifer performance was tested in 280 locations of the study area to assess the hydraulic characteristics of the various aquifers, potential yield from the flowing boreholes of both hard rocks and sedimentary formation underlain Zamfara State Northwestern, Nigeria. Pumping test result were subjected to standard methods of Jacob’s and modified Theis equation for evaluation of aquifer parameters such as hydraulic conductivity (K), Transmissivity (T), Specific capacity and others. The results show that characteristic of areas underlain by crystalline rock units, especially migmatite, variably migmatized gneiss, schists and granites are characterized by thin/shallow overburden unit of usually less than 10m. In such settings the borehole depth varies from 38 to 78m while saturated thickness varies from 8 to 20m below ground level, with average yield of 44.1m3/day. Hydrogeological parameters obtained from pumping test analysis within the basement rock units revealed aquifer transmissivity (T) values which range from 0.14 to 141.23m2/day, with an average of 12.85m2/day. This implies aquifers of negligible to high potentials. The hydraulic conductivity (K) values vary from 5.0 x 10-2m/day and 8.8 x 10-1m/day with an average of 2.2 x 10-1m/day. The implication of these results is that the aquifers of the basement rock units cannot provide sufficient water for both domestic and agricultural needs of the area. However, Sixty-eight (68) analyzed borehole data set within Gundumi Formation, revealed the average discharge rate of 116.8m3/day. This formation shows the highest water discharge within the study area. The average penetration depth of 65m was achieved. The hydraulic conductivity of this aquifer revealed average value of 5.7 × 10-1m/day. This implies high permeability of aquifer system, which is typical of sedimentary formation of this nature. Transmissivity (T) revealed an average value of 38.89m2/day, which indicate high rate of water flow through the entire aquifer medium of this formation. The geospatial analysis of yield from the wells indicate excellent groundwater potential around the western part of the study area.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
尼日利亚西北部典型基底复合体及Gundumi组含水层特征及地下水流动系统
在研究区域的280个地点测试了含水层的性能,以评估各种含水层的水力特性,以及尼日利亚Zamfara州西北地区坚硬岩石和沉积地层流动井眼的潜在产量。抽水试验结果采用标准的Jacob’s方法和修正的Theis方程来评价含水层参数,如水导率(K)、透射率(T)、比容等。结果表明:结晶岩单元下伏的地区,特别是混辉岩、变混辉化片麻岩、片岩和花岗岩的特征是薄/浅覆盖单元,通常小于10m;井深38 ~ 78m,饱和厚度8 ~ 20m,平均产量44.1m3/d。通过基岩单元内抽水试验分析得到的水文地质参数显示,含水层透过率(T)值为0.14 ~ 141.23m2/d,平均为12.85m2/d。这意味着可以忽略不计到高电位的含水层。水导率(K)值在5.0 × 10-2m/天和8.8 × 10-1m/天之间变化,平均值为2.2 × 10-1m/天。这些结果的含义是,基岩单元的含水层不能为该地区的家庭和农业需求提供足够的水。然而,68公司分析了Gundumi地层的井眼数据集,发现平均排放量为116.8m3/天。该地层显示出研究区内最高的排水量。平均侵彻深度达到65m。该含水层的水导率平均值为5.7 × 10-1m/d。这表明含水层系统具有高渗透率,是这种性质的沉积地层的典型特征。透射率(T)平均值为38.89m2/d,表明该地层整个含水层介质具有较高的水流速率。井产量的地理空间分析表明,研究区西部具有良好的地下水潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Potential of cattle rumen waste as a source of antibioticresistant bacteria dissemination in the environment Prevalence of typhoid fever among patients attending Murtala Muhammad Specialist Hospital Kano Bacteriological assessments of indoor air in the staff quarters of a tertiary institution in Benin City, Nigeria Effects of alcohol-graded concentrations on total thiols and some thiol utilizing enzymes Evaluation of bacteriological contamination of palms of pupils in the University of Benin Teaching Hospital Staff School, Benin City, Nigeria
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1