Transformadores de Potencia con Doble Núcleo: Análisis de respuesta a la frecuencia

C. Rojas, Sigridt Garcí­a Martínez
{"title":"Transformadores de Potencia con Doble Núcleo: Análisis de respuesta a la frecuencia","authors":"C. Rojas, Sigridt Garcí­a Martínez","doi":"10.35830/CN.VI82.543","DOIUrl":null,"url":null,"abstract":"The Frequency Response Analysis (FRA), is an excellent tool for the diagnosis and detection of internal faults in a transformer, such as: a displacement and winding deformation due to electromagnetic forces as a result of fault currents, the loosening of winding supports as a consequence of electric shocks or when the transformer is transported. These type of faults are mainly involved with the change in the geometry of the transfomer as a whole, a factor that alters the RLC parameters which represent the transformer, and therefore, its resonance points. The standard behavior of the three-phase three limbs transformer can be found in the literature. In this work, an analysis of the tests, which were applied in a double core transformer that is commoly used in arc furnaces, was carried out. The main feature of these transformers is that they feed high currents over a wide range of voltages.","PeriodicalId":100317,"journal":{"name":"Computer Networks and ISDN Systems","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Networks and ISDN Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35830/CN.VI82.543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Frequency Response Analysis (FRA), is an excellent tool for the diagnosis and detection of internal faults in a transformer, such as: a displacement and winding deformation due to electromagnetic forces as a result of fault currents, the loosening of winding supports as a consequence of electric shocks or when the transformer is transported. These type of faults are mainly involved with the change in the geometry of the transfomer as a whole, a factor that alters the RLC parameters which represent the transformer, and therefore, its resonance points. The standard behavior of the three-phase three limbs transformer can be found in the literature. In this work, an analysis of the tests, which were applied in a double core transformer that is commoly used in arc furnaces, was carried out. The main feature of these transformers is that they feed high currents over a wide range of voltages.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双芯电力变压器:频率响应分析
频率响应分析(FRA)是诊断和检测变压器内部故障的绝佳工具,例如:由于故障电流引起的电磁力引起的位移和绕组变形,由于电击或变压器运输时绕组支架松动。这些类型的故障主要与变压器整体几何形状的变化有关,这一因素改变了代表变压器的RLC参数,因此也改变了它的谐振点。三相三肢变压器的标准性能可以在文献中找到。本文对电弧炉中常用的双芯变压器的试验结果进行了分析。这些变压器的主要特点是它们在很宽的电压范围内提供大电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Exploración sísmica de refracción mediante ruido sísmico La lógica de la gestión del riesgo volcánico Aplicación de VolcFlow para simular Avalanchas de Escombros y CDP en los volcanes Popocatépetl, Volcán de Colima y Ceboruco Transformadores de Potencia con Doble Núcleo: Análisis de respuesta a la frecuencia Caracterización de un holograma mediante el dopaje de un PDLC con violeta de genciana
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1