{"title":"Facile in-situ preparation of few-layered reduced graphene oxide – niobium pentoxide composite for non-enzymatic glucose monitoring","authors":"Rinky Sha, L. Durai, Sushmee Badhulika","doi":"10.1109/icee44586.2018.8937860","DOIUrl":null,"url":null,"abstract":"This paper reports a novel and low cost hydrothermal method for the in-situ preparation of few-layered reduced graphene oxide – niobium pentoxide composite for non-enzymatic detection of glucose. TEM, XRD and Raman spectroscopic results confirmed the successful growth of few-layered two dimensional reduced graphene oxide – spherical niobium-pentoxide nanoparticles based (rGO-Nb2 O5) composite. The as-fabricated rGO-Nb2 O5 sensor exhibited a sensitivity of $3.23 \\mu\\mathrm{A}$. mM-1 with an excellent linearity (R2=0.994) in the physiological range of blood glucose (1-10 mM). The sensing ability of the composite based sensor towards glucose was explained in terms of forward biased nano Schottky barriers at the rGO-Nb2 O5 interface. This work further can be extended for the non-enzymatic detection of glucose in saliva, tears or urine samples.","PeriodicalId":6590,"journal":{"name":"2018 4th IEEE International Conference on Emerging Electronics (ICEE)","volume":"100 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th IEEE International Conference on Emerging Electronics (ICEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/icee44586.2018.8937860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
This paper reports a novel and low cost hydrothermal method for the in-situ preparation of few-layered reduced graphene oxide – niobium pentoxide composite for non-enzymatic detection of glucose. TEM, XRD and Raman spectroscopic results confirmed the successful growth of few-layered two dimensional reduced graphene oxide – spherical niobium-pentoxide nanoparticles based (rGO-Nb2 O5) composite. The as-fabricated rGO-Nb2 O5 sensor exhibited a sensitivity of $3.23 \mu\mathrm{A}$. mM-1 with an excellent linearity (R2=0.994) in the physiological range of blood glucose (1-10 mM). The sensing ability of the composite based sensor towards glucose was explained in terms of forward biased nano Schottky barriers at the rGO-Nb2 O5 interface. This work further can be extended for the non-enzymatic detection of glucose in saliva, tears or urine samples.