Work function behavior of a biased C12A7 electride in low temperature hydrogen plasmas

A. Heiler, R. Friedl, U. Fantz, R. Nocentini, M. Sasao
{"title":"Work function behavior of a biased C12A7 electride in low temperature hydrogen plasmas","authors":"A. Heiler, R. Friedl, U. Fantz, R. Nocentini, M. Sasao","doi":"10.1063/5.0057482","DOIUrl":null,"url":null,"abstract":"The development of ion sources for NNBI systems at future fusion devices like ITER or DEMO is based on the surface production of negative hydrogen ions. Thus, low work function converter surfaces are mandatory. Besides the state-of-the-art technique of continuous Cs injection during ion source operation, alternative materials are desirable to overcome the drawbacks of volatile Cs coatings. In this work, a C12A7 electride material is studied regarding the work function behavior in a hydrogen and deuterium plasma environment at ion source relevant conditions. The minimum measured work function obtained during the campaign is 2.9 ± 0.1 eV, with an optimization potential to lower values at better vacuum conditions and higher annealing temperatures. Biasing the sample during plasma operation exhibits a strong impact on the work function performance, which is dependent on the polarity and the applied bias potential. The minimum work function obtained for the C12A7 electride used in this experiment is substantially higher than what is achieved with in situ caesiation (~ 2 eV), but the sample has demonstrated promising properties in terms of plasma resilience.","PeriodicalId":21797,"journal":{"name":"SEVENTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2020)","volume":"13 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEVENTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2020)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0057482","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The development of ion sources for NNBI systems at future fusion devices like ITER or DEMO is based on the surface production of negative hydrogen ions. Thus, low work function converter surfaces are mandatory. Besides the state-of-the-art technique of continuous Cs injection during ion source operation, alternative materials are desirable to overcome the drawbacks of volatile Cs coatings. In this work, a C12A7 electride material is studied regarding the work function behavior in a hydrogen and deuterium plasma environment at ion source relevant conditions. The minimum measured work function obtained during the campaign is 2.9 ± 0.1 eV, with an optimization potential to lower values at better vacuum conditions and higher annealing temperatures. Biasing the sample during plasma operation exhibits a strong impact on the work function performance, which is dependent on the polarity and the applied bias potential. The minimum work function obtained for the C12A7 electride used in this experiment is substantially higher than what is achieved with in situ caesiation (~ 2 eV), but the sample has demonstrated promising properties in terms of plasma resilience.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
偏置C12A7电极在低温氢等离子体中的功函数行为
未来核聚变装置(如ITER或DEMO)中NNBI系统离子源的开发是基于负氢离子的表面产生。因此,低功函数转换器表面是强制性的。除了在离子源操作过程中连续注入Cs的最新技术外,还需要替代材料来克服挥发性Cs涂层的缺点。在离子源相关条件下,研究了C12A7电极材料在氢、氘等离子体环境中的功函数行为。在此过程中获得的最小测量功函数为2.9±0.1 eV,在更好的真空条件和更高的退火温度下具有更低的优化潜力。在等离子体操作过程中,偏置样品对功函数性能有很强的影响,这取决于极性和施加的偏置电位。本实验中使用的C12A7电极获得的最小功函数大大高于原位铯化(~ 2 eV),但样品在等离子体弹性方面表现出了很好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dynamic analysis on supporting structure of air borne vehicle subjected to random vibrations Recent achievements in studies of negative beam formation and acceleration in the tandem accelerator at Budker Institute Experimental study on foam concrete with polypropylene fibers and Nylon fibers Prediction of negative hydrogen ion density in permanent magnet-based helicon ion source (HELEN) using deep learning techniques Analysis on slot curvature and contact stresses on Geneva wheel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1