Closed-loop fuzzy control of resuscitation of hemorrhagic shock in sheep

Hao Ying, C. A. Bonnerup, Robert A. Kirschner, D. Deyo, Michael W. Michell, George C. Kramer
{"title":"Closed-loop fuzzy control of resuscitation of hemorrhagic shock in sheep","authors":"Hao Ying, C. A. Bonnerup, Robert A. Kirschner, D. Deyo, Michael W. Michell, George C. Kramer","doi":"10.1109/IEMBS.2002.1106545","DOIUrl":null,"url":null,"abstract":"Fluid therapy of severe hemorrhage and trauma can be life saving, but can also be life threatening if the volume delivered is either inadequate or excessive. Unfortunately, expert caregivers often do not have the time to focus on controlling fluid infusion rate due to the necessity of dealing with other critical tasks. We describe an automated closed-loop resuscitation system that uses a fuzzy logic controller to adjust infusion rate based on arterial pressure. The system was used to successfully resuscitate hemorrhaged sheep.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":"13 1","pages":"1575-1576 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1106545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Fluid therapy of severe hemorrhage and trauma can be life saving, but can also be life threatening if the volume delivered is either inadequate or excessive. Unfortunately, expert caregivers often do not have the time to focus on controlling fluid infusion rate due to the necessity of dealing with other critical tasks. We describe an automated closed-loop resuscitation system that uses a fuzzy logic controller to adjust infusion rate based on arterial pressure. The system was used to successfully resuscitate hemorrhaged sheep.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
绵羊失血性休克复苏的闭环模糊控制
严重出血和创伤的液体治疗可以挽救生命,但如果供水量不足或过量,也可能危及生命。不幸的是,由于处理其他关键任务的必要性,专业护理人员往往没有时间专注于控制液体输注速率。我们描述了一个自动闭环复苏系统,该系统使用模糊逻辑控制器根据动脉压力调节输液速率。该系统被用于成功复苏出血的绵羊。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
368
期刊最新文献
Contour extraction of fetus' head from echocardiogram using Snakes Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems Left ventricular volume changes after defibrillation Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT Comparative in vivo and ex vivo pacing and sensing performance study using isolated four-chamber working swine heart model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1