F. Loizeau, Hans Peter Lang, Terunobu Akiyama, S. Gautsch, P. Vettiger, A. Tonin, Genki Yoshikawa, C. Gerber, N. D. Rooij
{"title":"Piezoresistive membrane-type surface stress sensor arranged in arrays for cancer diagnosis through breath analysis","authors":"F. Loizeau, Hans Peter Lang, Terunobu Akiyama, S. Gautsch, P. Vettiger, A. Tonin, Genki Yoshikawa, C. Gerber, N. D. Rooij","doi":"10.1109/MEMSYS.2013.6474318","DOIUrl":null,"url":null,"abstract":"We present the fabrication, characterization and successful medical application of a membrane-type surface stress sensor (MSS), arranged in arrays for molecular detection in gaseous phase. Made out of SOI substrate, a round membrane with a diameter of 500 μm and a thickness of 2.5 μm is suspended by four sensing beams with integrated p-type piezoresistors, composing a full Wheatstone bridge. The membrane is coated with a thin polymer layer, which reacts with volatile molecules and produces a deflection of the membrane. The membranes were functionalized with various polymers and characterized as humidity sensors with a sensitivity of 87 mV/%RH and a time constant (Tau63%) of 1.3 s. Finally, through breath analysis and the use of principal component analysis (PCA), we were able, in a double blind trial, to distinguish cancer patients and healthy persons.","PeriodicalId":92162,"journal":{"name":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","volume":"33 1","pages":"621-624"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2013.6474318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
We present the fabrication, characterization and successful medical application of a membrane-type surface stress sensor (MSS), arranged in arrays for molecular detection in gaseous phase. Made out of SOI substrate, a round membrane with a diameter of 500 μm and a thickness of 2.5 μm is suspended by four sensing beams with integrated p-type piezoresistors, composing a full Wheatstone bridge. The membrane is coated with a thin polymer layer, which reacts with volatile molecules and produces a deflection of the membrane. The membranes were functionalized with various polymers and characterized as humidity sensors with a sensitivity of 87 mV/%RH and a time constant (Tau63%) of 1.3 s. Finally, through breath analysis and the use of principal component analysis (PCA), we were able, in a double blind trial, to distinguish cancer patients and healthy persons.