De-Bottlenecking of Existing Flare System for Facility Up-Gradation using Dynamic Simulation Approach - Case Study

R. Wasnik, H. Singh, F. Kamal, Oussama Takieddine
{"title":"De-Bottlenecking of Existing Flare System for Facility Up-Gradation using Dynamic Simulation Approach - Case Study","authors":"R. Wasnik, H. Singh, F. Kamal, Oussama Takieddine","doi":"10.2118/192750-ms","DOIUrl":null,"url":null,"abstract":"\n In today's oil prices scenario, industry's focus is shifting towards Brownfield projects having low CAPEX utilizing existing Oil & Gas assets. Towards this objective, de-bottlenecking of existing flare system becomes inevitable for facilities up-gradation. The spare capacity of existing flare is utilized to accommodate additional relief loads from new facility, thus avoiding installation of new flare. Dynamic simulation approach provides significant advantages over conventional approach in terms of realistic estimation of flare capacity and optimal use of existing plant assets.\n The conventional steady state approach assumptions provide conservative relief loads considering sum of instantaneous peak flows of relieving devices irrespective of their opening time. Flare operations are inherently dynamic in nature and dynamic simulations provide more realistic relief loads and presents optimal approach to de-bottlenecking of existing flare system.\n Latest API approach to determine relief rate based on Fire Response Analysis using vessel rupture acceptance criteria also provides additional benefits in terms of relief load optimization as compared to conventional API approach to reduce the system pressure to 50% or 100 Psig in 15 minutes.\n Dynamic approach also accounts for the packing effect in flare network, system operating pressure at which blow down will initiate and sequential opening of blow down valves for each isolatable section. Thus, dynamic approach provides better understanding of the dynamic behavior during blow down scenario. The flare system of offshore gas processing platform was originally designed based on steady state approach, commonly used being a conservative design which is more appropriate for green-field projects. In this approach, the total flare design load is established by adding all individual loads; assuming that peak flow from all sources will occur at the same time resulting in overdesign of flare system.\n A dynamic simulation model was developed to analyze the behavior of flare system during emergency relief scenario incorporating the actual volumes of Flare KOD, sub/main flare header and actual opening time of blowdown valves. The dynamic approach accounts for the packing phenomena in the overall flare system network which significantly optimizes the design of flare system and associated equipment.\n The results of dynamic approach are compared with conservative conventional approach. The study concludes that dynamic approach for flare system design provides more accurate estimation of peak flare load.","PeriodicalId":11014,"journal":{"name":"Day 1 Mon, November 12, 2018","volume":"11 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 1 Mon, November 12, 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/192750-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In today's oil prices scenario, industry's focus is shifting towards Brownfield projects having low CAPEX utilizing existing Oil & Gas assets. Towards this objective, de-bottlenecking of existing flare system becomes inevitable for facilities up-gradation. The spare capacity of existing flare is utilized to accommodate additional relief loads from new facility, thus avoiding installation of new flare. Dynamic simulation approach provides significant advantages over conventional approach in terms of realistic estimation of flare capacity and optimal use of existing plant assets. The conventional steady state approach assumptions provide conservative relief loads considering sum of instantaneous peak flows of relieving devices irrespective of their opening time. Flare operations are inherently dynamic in nature and dynamic simulations provide more realistic relief loads and presents optimal approach to de-bottlenecking of existing flare system. Latest API approach to determine relief rate based on Fire Response Analysis using vessel rupture acceptance criteria also provides additional benefits in terms of relief load optimization as compared to conventional API approach to reduce the system pressure to 50% or 100 Psig in 15 minutes. Dynamic approach also accounts for the packing effect in flare network, system operating pressure at which blow down will initiate and sequential opening of blow down valves for each isolatable section. Thus, dynamic approach provides better understanding of the dynamic behavior during blow down scenario. The flare system of offshore gas processing platform was originally designed based on steady state approach, commonly used being a conservative design which is more appropriate for green-field projects. In this approach, the total flare design load is established by adding all individual loads; assuming that peak flow from all sources will occur at the same time resulting in overdesign of flare system. A dynamic simulation model was developed to analyze the behavior of flare system during emergency relief scenario incorporating the actual volumes of Flare KOD, sub/main flare header and actual opening time of blowdown valves. The dynamic approach accounts for the packing phenomena in the overall flare system network which significantly optimizes the design of flare system and associated equipment. The results of dynamic approach are compared with conservative conventional approach. The study concludes that dynamic approach for flare system design provides more accurate estimation of peak flare load.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用动态仿真方法解决现有设施升级照明弹系统的瓶颈问题-案例研究
在当前的油价形势下,行业的重点正在转向利用现有油气资产进行低资本支出的棕地项目。为了实现这一目标,现有火炬系统的去瓶颈成为设施升级的必然。现有照明弹的剩余容量被用来容纳来自新设施的额外减压负荷,从而避免安装新的照明弹。动态模拟方法在实际估计火炬容量和优化现有工厂资产利用方面比传统方法具有显著优势。传统的稳态方法假设提供了保守的卸荷,考虑卸荷装置的瞬时峰值流量之和,而不考虑卸荷装置的开启时间。耀斑操作本质上是动态的,动态模拟提供了更真实的救援负荷,并为现有耀斑系统的瓶颈消除提供了最佳方法。与传统的API方法相比,最新的API方法基于使用容器破裂验收标准的火灾响应分析来确定减压率,在减压负荷优化方面也提供了额外的好处,可以在15分钟内将系统压力降低到50%或100 Psig。动态方法还考虑了火炬网络中的填料效应、启动放空的系统工作压力以及每个可隔离段的放空阀的顺序打开。因此,动态方法可以更好地理解吹风过程中的动态行为。海上天然气处理平台火炬系统最初是基于稳态方法设计的,通常采用保守设计,更适合于新建项目。在这种方法中,总火炬设计载荷是通过将所有单个载荷相加来确定的;假设所有源的峰值流量将同时出现,导致火炬系统的过度设计。基于火炬KOD的实际体积、副/主火炬箱的实际体积和放空阀的实际开启时间,建立了火炬系统在紧急救援场景下的动态仿真模型。动态方法考虑了整个火炬系统网络中的堆积现象,对火炬系统及相关设备的设计具有重要的优化作用。将动态方法的结果与保守的传统方法进行了比较。研究表明,采用动态方法设计耀斑系统能更准确地估计耀斑峰值负荷。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Does the kappa number method accurately reflect lignin content in nonwood pulps? Using multistage models to evaluate how pulp washing after the first extraction stage impacts elemental chlorine-free bleach demand Understanding the risks and rewards of using 50% vs. 10% strength peroxide in pulp bleach plants Understanding the pulping and bleaching performances of eucalyptus woods affected by physiological disturbance Measurements of the Inorganic Scale Buildup Rate on Downhole Completion Equipment – Debris Barrier Screens
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1