Microwave Ablation Trocar Operated At Dual Tine Dual-frequency: A Numerical Analysis

Satish Vellavalapalli, R. Repaka
{"title":"Microwave Ablation Trocar Operated At Dual Tine Dual-frequency: A Numerical Analysis","authors":"Satish Vellavalapalli, R. Repaka","doi":"10.1115/1.4056410","DOIUrl":null,"url":null,"abstract":"\n Microwave ablation (MWA) is a minimally invasive thermal ablation technique that has the advantages of obtaining high intratumoral temperatures, less treatment time and large ablation region as compared to other thermal ablation techniques. The ablation region obtained during MWA procedure mainly depends on the design and type of the trocar being used. The trocar plays an essential role in the MWA system by governing the energy distribution during tissue ablation. In this study, a novel MWA trocar design has been considered to achieve concentrated ablation region along the tumor's spatial distribution. A dual tine trocar with each tine supplied with energy at different frequencies (2.45 GHz and 6 GHz) has been considered for tumor ablation. Commercially available Finite Element based software has been used (COMSOL-Multiphysics) to analyze the extent of ablation zone. Coupled bioheat and electromagnetic physics interfaces have been utilized. Results showed that the proposed trocar with tines operating at 6 GHz on both the tines leads to a large ablation region (3 cm in diameter) with spherical in shape. Irregularly shaped ablation region can also be achieved by this trocar with tines operating at different frequencies. The minimum time required for complete tumor ablation by the trocar operated at 6 GHz is 4 minutes, followed by 6 minutes for the trocar operated at 2.45 GHz. The proposed trocar can become a part of a better treatment planning system (TPS) based on tumor shape, nearby blood vessel presence, and the trocar's precise insertion.","PeriodicalId":73734,"journal":{"name":"Journal of engineering and science in medical diagnostics and therapy","volume":"23 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of engineering and science in medical diagnostics and therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4056410","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Microwave ablation (MWA) is a minimally invasive thermal ablation technique that has the advantages of obtaining high intratumoral temperatures, less treatment time and large ablation region as compared to other thermal ablation techniques. The ablation region obtained during MWA procedure mainly depends on the design and type of the trocar being used. The trocar plays an essential role in the MWA system by governing the energy distribution during tissue ablation. In this study, a novel MWA trocar design has been considered to achieve concentrated ablation region along the tumor's spatial distribution. A dual tine trocar with each tine supplied with energy at different frequencies (2.45 GHz and 6 GHz) has been considered for tumor ablation. Commercially available Finite Element based software has been used (COMSOL-Multiphysics) to analyze the extent of ablation zone. Coupled bioheat and electromagnetic physics interfaces have been utilized. Results showed that the proposed trocar with tines operating at 6 GHz on both the tines leads to a large ablation region (3 cm in diameter) with spherical in shape. Irregularly shaped ablation region can also be achieved by this trocar with tines operating at different frequencies. The minimum time required for complete tumor ablation by the trocar operated at 6 GHz is 4 minutes, followed by 6 minutes for the trocar operated at 2.45 GHz. The proposed trocar can become a part of a better treatment planning system (TPS) based on tumor shape, nearby blood vessel presence, and the trocar's precise insertion.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双时双频微波消融套管针的数值分析
微波消融(MWA)是一种微创热消融技术,与其他热消融技术相比,具有瘤内温度高、治疗时间短、消融面积大等优点。在MWA过程中获得的消融区域主要取决于所使用的套管针的设计和类型。套管针通过控制组织消融过程中的能量分布在MWA系统中起着至关重要的作用。在这项研究中,一种新的MWA套管针设计被认为可以沿着肿瘤的空间分布实现集中消融区域。双时间套管针每次提供不同频率(2.45 GHz和6 GHz)的能量已被考虑用于肿瘤消融。利用商用有限元软件(COMSOL-Multiphysics)对烧蚀区范围进行了分析。利用了生物热和电磁物理耦合界面。结果表明:所设计的套管针在6 GHz频率下工作,导致了一个直径为3 cm的球形大烧蚀区。在不同频率下,套管针也可以实现不规则形状的消融区域。使用6 GHz频率的套管针完成肿瘤消融所需的最短时间为4分钟,其次是使用2.45 GHz频率的套管针,最短时间为6分钟。所提出的套管针可以成为更好的治疗计划系统(TPS)的一部分,该系统基于肿瘤形状、附近血管的存在以及套管针的精确插入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
High-Speed Three-Dimensional-Digital Image Correlation and Schlieren Imaging Integrated With Shock Tube Loading for Investigating Dynamic Response of Human Tympanic Membrane Exposed to Blasts. Quantifying the Fascicular Changes in Recovered Achilles Tendon Patients Using Diffusion Magnetic Resonance Imaging and Tractography. Assistive Technology for Real-Time Fall Prevention during Walking: Evaluation of the Effect of an Intelligent Foot Orthosis A Simple Poc Device for Temperature Control of Multiple Reactions During Recombinase Polymerase Amplification Auxetic Structure Inspired Microneedle Arrays for Minimally Invasive Drug Delivery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1