{"title":"Fire Risk Rating Assessment for Wood Specimens Coated with Flame Retardant","authors":"Eui Jin, Yeong-Jin Chung","doi":"10.33696/nanotechnol.4.041","DOIUrl":null,"url":null,"abstract":"Chung's equations-II, -III, and -IV were applied to evaluate the fire risk and fire risk ratings of flame retardants. As an example, a wood specimen coated with a flame retardant was selected and tested using a cone calorimeter according to the ISO 5660-1 standard. The external heat flux was fixed to 50 kW/m2. Fire performance index-III used three variables to evaluate the initial fire risk: the time to ignition, first peak heat release rate, and first peak smoke release rate. Fire growth index-III was calculated using the first peak heat release rate, peak smoke production rate, and time to reach the first peak smoke production rate. This index is a standardized fire hazard category with poly(methyl methacrylate) as the reference material. The fire risk rating index, fire risk index-IV, is expressed as the value obtained by dividing the fire growth index-III by fire performance index-III. In this study, the methodology for fire risk rating evaluation is discussed.","PeriodicalId":94095,"journal":{"name":"Journal of nanotechnology and nanomaterials","volume":"2016 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nanotechnology and nanomaterials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33696/nanotechnol.4.041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Chung's equations-II, -III, and -IV were applied to evaluate the fire risk and fire risk ratings of flame retardants. As an example, a wood specimen coated with a flame retardant was selected and tested using a cone calorimeter according to the ISO 5660-1 standard. The external heat flux was fixed to 50 kW/m2. Fire performance index-III used three variables to evaluate the initial fire risk: the time to ignition, first peak heat release rate, and first peak smoke release rate. Fire growth index-III was calculated using the first peak heat release rate, peak smoke production rate, and time to reach the first peak smoke production rate. This index is a standardized fire hazard category with poly(methyl methacrylate) as the reference material. The fire risk rating index, fire risk index-IV, is expressed as the value obtained by dividing the fire growth index-III by fire performance index-III. In this study, the methodology for fire risk rating evaluation is discussed.