Metabolomics Distinction of Cigarette Smokers from Non-Smokers Using Non-Stationary Benchtop Nuclear Magnetic Resonance (NMR) Analysis of Human Saliva

Benita C. Percival, A. Wann, S. Taylor, Mark Edgar, Miles Gibson, M. Grootveld
{"title":"Metabolomics Distinction of Cigarette Smokers from Non-Smokers Using Non-Stationary Benchtop Nuclear Magnetic Resonance (NMR) Analysis of Human Saliva","authors":"Benita C. Percival, A. Wann, S. Taylor, Mark Edgar, Miles Gibson, M. Grootveld","doi":"10.5772/intechopen.101414","DOIUrl":null,"url":null,"abstract":"Implementations of high-field nuclear magnetic resonance (NMR) facilities into metabolomics studies are unfortunately restricted by their large dimensions, high costings, and specialist technical staff requirements. Therefore, here the application and practical advantages offered by low-field (60 MHz), compact NMR spectrometers for probing the metabolic profiles of human saliva was explored, as was their value in salivary metabolomics studies. Saliva samples were collected from cigarette smoking (n = 11) and non-smoking (n = 31) human participants. 1H NMR spectra were acquired on both low-field (60 MHz) and medium-field (400 MHz) spectrometers. Metabolomics analyses were employed to evaluate the consistencies of salivary metabolite levels determined, and their abilities to distinguish between smokers and non-smokers. Low-field 1H NMR analysis detected up to 15, albeit permitted the reliable quantification of 5, potentially key diagnostic biomolecules simultaneously (LLOQ values 250–400 μmol/L), although these were limited to those with the most prominent resonances. Such low-field profiles were also found to be suitable for salivary metabolomics investigations, which confirmed the successful discrimination between smoking and non-smoking participant sample donors. Differences observed between these groups were largely ascribable to upregulated salivary levels of methanol, and its metabolite formate, in the smoking group, but higher smoking-mediated concentrations of acetate, propionate and glycine may arise from a diminished salivary flow-rate in these participants. In conclusion, determination of salivary biomolecules using low-field, benchtop 1H NMR analysis techniques were found to be valuable for bioanalytical and metabolomics investigations. Future perspectives for the applications of this non-stationary NMR technique, for example for the on-site ‘point-of-care’ testing of saliva samples for diagnostic oral disease screening purposes at dental surgeries and community pharmacies, are considered.","PeriodicalId":19603,"journal":{"name":"Oral Health Care [Working Title]","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Health Care [Working Title]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5772/intechopen.101414","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Implementations of high-field nuclear magnetic resonance (NMR) facilities into metabolomics studies are unfortunately restricted by their large dimensions, high costings, and specialist technical staff requirements. Therefore, here the application and practical advantages offered by low-field (60 MHz), compact NMR spectrometers for probing the metabolic profiles of human saliva was explored, as was their value in salivary metabolomics studies. Saliva samples were collected from cigarette smoking (n = 11) and non-smoking (n = 31) human participants. 1H NMR spectra were acquired on both low-field (60 MHz) and medium-field (400 MHz) spectrometers. Metabolomics analyses were employed to evaluate the consistencies of salivary metabolite levels determined, and their abilities to distinguish between smokers and non-smokers. Low-field 1H NMR analysis detected up to 15, albeit permitted the reliable quantification of 5, potentially key diagnostic biomolecules simultaneously (LLOQ values 250–400 μmol/L), although these were limited to those with the most prominent resonances. Such low-field profiles were also found to be suitable for salivary metabolomics investigations, which confirmed the successful discrimination between smoking and non-smoking participant sample donors. Differences observed between these groups were largely ascribable to upregulated salivary levels of methanol, and its metabolite formate, in the smoking group, but higher smoking-mediated concentrations of acetate, propionate and glycine may arise from a diminished salivary flow-rate in these participants. In conclusion, determination of salivary biomolecules using low-field, benchtop 1H NMR analysis techniques were found to be valuable for bioanalytical and metabolomics investigations. Future perspectives for the applications of this non-stationary NMR technique, for example for the on-site ‘point-of-care’ testing of saliva samples for diagnostic oral disease screening purposes at dental surgeries and community pharmacies, are considered.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用非静止台式核磁共振(NMR)分析人类唾液的吸烟者和非吸烟者的代谢组学区别
不幸的是,高场核磁共振(NMR)设备在代谢组学研究中的应用受到其大尺寸、高成本和专业技术人员要求的限制。因此,本文探讨了低场(60 MHz)紧凑型核磁共振光谱仪用于探测人类唾液代谢谱的应用和实际优势,以及它们在唾液代谢组学研究中的价值。从吸烟(n = 11)和不吸烟(n = 31)的人类参与者中收集唾液样本。在低场(60 MHz)和中场(400 MHz)光谱仪上获取1H NMR谱。代谢组学分析用于评估唾液代谢物水平测定的一致性,以及它们区分吸烟者和非吸烟者的能力。低场1H NMR分析检测到多达15个,尽管允许同时可靠地定量5个,潜在的关键诊断生物分子(LLOQ值250-400 μmol/L),尽管这些仅限于那些最突出的共振。这种低场谱也被发现适合于唾液代谢组学调查,这证实了吸烟和不吸烟参与者样本供体之间的成功区分。这些组之间观察到的差异主要归因于吸烟组唾液中甲醇及其代谢物甲酸酯水平的上调,但吸烟导致的醋酸盐、丙酸盐和甘氨酸浓度升高可能是由于这些参与者唾液流速的降低。总之,使用低场台式1H NMR分析技术测定唾液生物分子在生物分析和代谢组学研究中是有价值的。考虑了这种非平稳核磁共振技术应用的未来前景,例如在牙科手术和社区药房用于诊断口腔疾病筛查目的的唾液样本的现场“护理点”测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Oral Aspects and Dental Management of Special Needs Patient Preventive Methods and Treatments of White Spot Lesions in Orthodontics Metabolomics Distinction of Cigarette Smokers from Non-Smokers Using Non-Stationary Benchtop Nuclear Magnetic Resonance (NMR) Analysis of Human Saliva Management and Prevention Strategies for Treating Dentine Hypersensitivity Alternative Denture Base Materials for Allergic Patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1