Flexi-distortional piezoelectric sensor results

W. B. Carlson, S. Pilgrim, W. Schulze, Y. Kato, J. Frommelt
{"title":"Flexi-distortional piezoelectric sensor results","authors":"W. B. Carlson, S. Pilgrim, W. Schulze, Y. Kato, J. Frommelt","doi":"10.1109/ISAF.1994.522485","DOIUrl":null,"url":null,"abstract":"A longitudinal (\"RIBBIE\") form of a shear amplification sensor has been tested for amplified d/sub 15/ response. The mechanically amplified flexi-distortional system may improve the d/sub h/g/sub h/ figure of merit by transferring the compressional stress on the device to a lateral shear on the electroceramic element. This type of amplified system is mechanically classified as distortional and, therefore, without volume change By transforming the hydrostatic stress to transverse strain, the transverse forces can be used to develop shear strain and activate the d/sub 15/ coefficient. Electrodes are placed along the sides of the sensing element. Flexi-distortional devices are tested in order to check for the limits of sensitivity in their performance.","PeriodicalId":20488,"journal":{"name":"Proceedings of 1994 IEEE International Symposium on Applications of Ferroelectrics","volume":"3 1","pages":"770-771"},"PeriodicalIF":0.0000,"publicationDate":"1994-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 IEEE International Symposium on Applications of Ferroelectrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAF.1994.522485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A longitudinal ("RIBBIE") form of a shear amplification sensor has been tested for amplified d/sub 15/ response. The mechanically amplified flexi-distortional system may improve the d/sub h/g/sub h/ figure of merit by transferring the compressional stress on the device to a lateral shear on the electroceramic element. This type of amplified system is mechanically classified as distortional and, therefore, without volume change By transforming the hydrostatic stress to transverse strain, the transverse forces can be used to develop shear strain and activate the d/sub 15/ coefficient. Electrodes are placed along the sides of the sensing element. Flexi-distortional devices are tested in order to check for the limits of sensitivity in their performance.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
柔性变形压电传感器结果
纵向(“RIBBIE”)形式的剪切放大传感器已经测试了放大的d/sub / 15/响应。机械放大的挠性扭曲系统可以通过将器件上的压缩应力传递到电陶瓷元件上的横向剪切来提高d/sub h/g/sub h/优值。这种类型的放大系统在机械上被归类为扭曲的,因此没有体积变化。通过将静水应力转化为横向应变,横向力可以用来产生剪切应变并激活d/sub 15/系数。电极沿传感元件的两侧放置。对挠性扭曲器件进行测试,以检查其性能中的灵敏度极限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Spatial Resolution and Measurement Accuracy of Dielectric Microscope Using Non-contact State Microwave Probe Dependence on supermolecular structure and on charge injection conditions of ferroelectric switching of PVDF and its blends with PMMA High-efficiency ferro-piezoceramic PCR-type materials for various applications Characterization of PZT hollow-sphere transducers Growth and properties of tungsten-bronze ferroelectric potassium lithium niobate single crystals for optical applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1