T. Sandner, T. Grasshoff, M. Schwarzenberg, H. Schenk
{"title":"Quasi-static microscanner with linearized scanning for an adaptive 3D-laser camera","authors":"T. Sandner, T. Grasshoff, M. Schwarzenberg, H. Schenk","doi":"10.1117/12.2064898","DOIUrl":null,"url":null,"abstract":"This paper presents a gimbaled MEMS scanning mirror especially developed for adaptive raster scanning in a novel 3D-ToF laser camera. Substantial quasi-static deflections of ±10° are provided by vertical comb drives in vertical direction in contrast to resonant horizontal scanning of the 2.6×3.6mm elliptical mirror at 1600Hz and 80° FOV. To guarantee the full reception aperture of effective 5mm a synchronized driven array - consisting of five hybrid assembled MEMS devices with integrated position feedback - is used by the 3D camera enabling a distance measuring rate of 1MVoxel/s and an uncertainty of ToF distance measurement of 5mm at 7.5m.","PeriodicalId":6334,"journal":{"name":"2013 International Conference on Optical MEMS and Nanophotonics (OMN)","volume":"131 1","pages":"103-104"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Optical MEMS and Nanophotonics (OMN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2064898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
This paper presents a gimbaled MEMS scanning mirror especially developed for adaptive raster scanning in a novel 3D-ToF laser camera. Substantial quasi-static deflections of ±10° are provided by vertical comb drives in vertical direction in contrast to resonant horizontal scanning of the 2.6×3.6mm elliptical mirror at 1600Hz and 80° FOV. To guarantee the full reception aperture of effective 5mm a synchronized driven array - consisting of five hybrid assembled MEMS devices with integrated position feedback - is used by the 3D camera enabling a distance measuring rate of 1MVoxel/s and an uncertainty of ToF distance measurement of 5mm at 7.5m.