Self-sensing active artificial hair cells inspired by the cochlear amplifier, Part II: Experimental validation

IF 2.4 3区 材料科学 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY Journal of Intelligent Material Systems and Structures Pub Date : 2023-04-11 DOI:10.1177/1045389X231164514
Sheyda Davaria, V. V. S. Malladi, P. Tarazaga
{"title":"Self-sensing active artificial hair cells inspired by the cochlear amplifier, Part II: Experimental validation","authors":"Sheyda Davaria, V. V. S. Malladi, P. Tarazaga","doi":"10.1177/1045389X231164514","DOIUrl":null,"url":null,"abstract":"Mimicking the nonlinear compressive behavior of the mammalian cochlear amplifier that results in the compression of high-intensity sounds and amplification of faint stimuli can lead to transformative improvements in the dynamic range, sharpness of the response, and threshold of sound detection in cochlear implants to aid individuals with hearing loss. Furthermore, it can enhance the dynamic properties of sensors. This research on developing self-sensing artificial hair cells (AHCs) validates the phenomenological control algorithm established in Part I of the paper to achieve a cochlea-like response from the quadmorph AHCs. As the beam is excited, the voltage of the piezoelectric layers is measured and used to generate a control voltage. Consequently, the controller applies cubic damping to the AHC, while reducing linear damping near its first natural frequency to replicate the biological cochlea’s function. Experimental results validate the model built in Part I of the paper and the work is extended to implement a multi-channel AHC. The system works independent of external sensors and offers significant advantages over previous generations of AHCs such as the ability to embed AHCs in a limited space and to combine several AHCs in an array without the need for external feedback measurement devices.","PeriodicalId":16121,"journal":{"name":"Journal of Intelligent Material Systems and Structures","volume":"21 1","pages":"2089 - 2105"},"PeriodicalIF":2.4000,"publicationDate":"2023-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Intelligent Material Systems and Structures","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1177/1045389X231164514","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Mimicking the nonlinear compressive behavior of the mammalian cochlear amplifier that results in the compression of high-intensity sounds and amplification of faint stimuli can lead to transformative improvements in the dynamic range, sharpness of the response, and threshold of sound detection in cochlear implants to aid individuals with hearing loss. Furthermore, it can enhance the dynamic properties of sensors. This research on developing self-sensing artificial hair cells (AHCs) validates the phenomenological control algorithm established in Part I of the paper to achieve a cochlea-like response from the quadmorph AHCs. As the beam is excited, the voltage of the piezoelectric layers is measured and used to generate a control voltage. Consequently, the controller applies cubic damping to the AHC, while reducing linear damping near its first natural frequency to replicate the biological cochlea’s function. Experimental results validate the model built in Part I of the paper and the work is extended to implement a multi-channel AHC. The system works independent of external sensors and offers significant advantages over previous generations of AHCs such as the ability to embed AHCs in a limited space and to combine several AHCs in an array without the need for external feedback measurement devices.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
由耳蜗放大器启发的自传感主动人造毛细胞,第二部分:实验验证
模拟哺乳动物人工耳蜗放大器的非线性压缩行为,导致高强度声音的压缩和微弱刺激的放大,可以导致人工耳蜗植入物的动态范围,响应的清晰度和声音检测阈值的革命性改进,以帮助听力损失的个体。此外,它还可以提高传感器的动态性能。本研究开发的自感人工毛细胞(AHCs)验证了本文第一部分建立的现象学控制算法,以实现四形人工毛细胞的耳蜗样反应。当光束被激发时,测量压电层的电压并用于产生控制电压。因此,控制器对AHC施加三次阻尼,同时减少其第一固有频率附近的线性阻尼,以复制生物耳蜗的功能。实验结果验证了本文第一部分建立的模型,并将工作扩展到实现多通道AHC。该系统独立于外部传感器工作,与前几代ahc相比具有显著优势,例如能够在有限的空间内嵌入ahc,并且无需外部反馈测量设备即可将多个ahc组合在一个阵列中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Intelligent Material Systems and Structures
Journal of Intelligent Material Systems and Structures 工程技术-材料科学:综合
CiteScore
5.40
自引率
11.10%
发文量
126
审稿时长
4.7 months
期刊介绍: The Journal of Intelligent Materials Systems and Structures is an international peer-reviewed journal that publishes the highest quality original research reporting the results of experimental or theoretical work on any aspect of intelligent materials systems and/or structures research also called smart structure, smart materials, active materials, adaptive structures and adaptive materials.
期刊最新文献
A modified parametric model to predict visco-elastic properties of magneto-rheological elastomers at non-LVE region Simultaneous position and force control of a SMA-actuated continuum robotic module A facile method to fabricate auxetic polymer foams A low-frequency multidirectional piezoelectric vibration energy harvester using a universal joint structure Development of a fail-safe magnetorheological fluid device using electro and permanent magnets
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1