{"title":"Parametric resonance magnetometer based on elliptically polarized light yielding three-axis measurement with isotropic sensitivity","authors":"Gwenael Le Gal, L. Rouve, A. Palacios-Laloy","doi":"10.1063/5.0047124","DOIUrl":null,"url":null,"abstract":"We present here a new parametric resonance magnetometer scheme based on elliptically polarized pumping light and two radio-frequency fields applied along the two optical pumping directions. At optimum ellipticity and radio-frequency fields amplitudes the three components of the magnetic field are measured with an isotropic sensitivity. Compared to the usual alignment-based parametric resonance magnetometers, the sensitivity is degraded by a factor 2 for two components of the magnetic field but improved by a factor 11 for the third one. This new magnetometer configuration could be particularly interesting for geophysics and biomedical imaging.","PeriodicalId":8441,"journal":{"name":"arXiv: Atomic Physics","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: Atomic Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0047124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
We present here a new parametric resonance magnetometer scheme based on elliptically polarized pumping light and two radio-frequency fields applied along the two optical pumping directions. At optimum ellipticity and radio-frequency fields amplitudes the three components of the magnetic field are measured with an isotropic sensitivity. Compared to the usual alignment-based parametric resonance magnetometers, the sensitivity is degraded by a factor 2 for two components of the magnetic field but improved by a factor 11 for the third one. This new magnetometer configuration could be particularly interesting for geophysics and biomedical imaging.