{"title":"Determination of glucosamine in dietary supplement samples by capillary electrophoresis using capacitively coupled contactless conductivity detector (CE-C4D)","authors":"Huyen My Dang Thi, Ngoc Ly Nguyen Thi, Nhi Do Yen, Diu Dinh Thi, Lan Phuong Kieu Thi, Anh Hoang Quoc, Nguyen Pham Hoang, Quynh Anh Pham Thi, Son Tran Cao, Minh Thu Nguyen Thi, Huy Nguyen Quang, Anh Huong Nguyen Thi","doi":"10.47866/2615-9252/vjfc.3935","DOIUrl":null,"url":null,"abstract":"The quantification of glucosamine in dietary supplements was investigated by using capillary with capacitively coupled contactless conductivity detection (CE-C4D). Optimal conditions included electrophoresis buffer solution 10 mM Tris/Ace; pH = 5,0; sample injection height 25 cm; sample injection time 30 s; separation voltage 20 kV. The limit of detection (LOD) and the limit of quantification (LOQ) of glucosamine were 8.00 ppm and 26.67 ppm, respectively. Calibration curve was constructed over the range from 20 to 1000 ppm giving a good linear correlation coefficient (R2 = 0.9993). The relative standard deviation (RSD) ranged from 1.28% to 2.33% (n = 3) and the recovery efficiency ranged from 95.2 to 102.3% which indicated good precision and trueness of our method. The method was applied to determine glucosamine in 4 dietary supplement samples randomly collected at the local markets. The CE-C4D results were compared with those obtained by reference HPLC-FLD method, showing good agreement between the two methods (relative error < 15%).","PeriodicalId":12896,"journal":{"name":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47866/2615-9252/vjfc.3935","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The quantification of glucosamine in dietary supplements was investigated by using capillary with capacitively coupled contactless conductivity detection (CE-C4D). Optimal conditions included electrophoresis buffer solution 10 mM Tris/Ace; pH = 5,0; sample injection height 25 cm; sample injection time 30 s; separation voltage 20 kV. The limit of detection (LOD) and the limit of quantification (LOQ) of glucosamine were 8.00 ppm and 26.67 ppm, respectively. Calibration curve was constructed over the range from 20 to 1000 ppm giving a good linear correlation coefficient (R2 = 0.9993). The relative standard deviation (RSD) ranged from 1.28% to 2.33% (n = 3) and the recovery efficiency ranged from 95.2 to 102.3% which indicated good precision and trueness of our method. The method was applied to determine glucosamine in 4 dietary supplement samples randomly collected at the local markets. The CE-C4D results were compared with those obtained by reference HPLC-FLD method, showing good agreement between the two methods (relative error < 15%).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电容偶联非接触式电导率检测器(CE-C4D)毛细管电泳法测定膳食补充剂样品中的葡萄糖胺
采用毛细管电容耦合非接触式电导率检测法(CE-C4D)对膳食补充剂中葡萄糖胺的定量进行了研究。最优条件为电泳缓冲液10 mM Tris/Ace;pH = 5,0;进样高度25cm;进样时间30 s;分离电压20kv。葡萄糖胺的检出限(LOD)为8.00 ppm,定量限(LOQ)为26.67 ppm。在20 ~ 1000 ppm范围内建立了校准曲线,具有良好的线性相关系数(R2 = 0.9993)。相对标准偏差(RSD)为1.28% ~ 2.33% (n = 3),回收率为95.2 ~ 102.3%,表明该方法精密度和准确度较高。采用该方法对在当地市场随机抽取的4种膳食补充剂样品中的氨基葡萄糖进行测定。CE-C4D结果与参考HPLC-FLD方法比较,结果吻合较好(相对误差< 15%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Producing positive control materials for template in PCR testing to detect botulinum neurotoxin types A and B genes Food safety knowledge and practices of vegetarian food processors in Hanoi in 2022-2023 Research and development of non-enzymatic electrochemical sensors utilizing porous ZnO/graphene electrodes to determine xanthine Study on coffee husk treatment by microorganisms A comprehensive study on reference material of Imidacloprid in tomato matrix
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1